From version < 54.15 >
edited by Xiaoling
on 2023/05/24 16:27
To version < 54.12 >
edited by Xiaoling
on 2023/04/04 10:59
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -59,6 +59,7 @@
59 59  * 8500mAh Battery for long-term use
60 60  
61 61  
62 +
62 62  == 1.3  Specification ==
63 63  
64 64  
... ... @@ -77,6 +77,7 @@
77 77  * B28 @H-FDD: 700MHz
78 78  
79 79  
81 +
80 80  == 1.4  Installation ==
81 81  
82 82  
... ... @@ -96,6 +96,7 @@
96 96  * Dry Contact Detection
97 97  
98 98  
101 +
99 99  == 1.6  Mechanical ==
100 100  
101 101  
... ... @@ -324,11 +324,11 @@
324 324  Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded.
325 325  
326 326  
327 -(% border="1" style="background-color:#f2f2f2; width:510px" %)
330 +(% border="1.5" style="background-color:#ffffcc; color:green; width:510px" %)
328 328  |=(% scope="row" style="width: 60px;" %)**Size(bytes)**|(% style="width:40px" %)**8**|(% style="width:20px" %)**2**|(% style="width:20px" %)**2**|(% style="width:80px" %)**1**|(% style="width:40px" %)**1**|(% style="width:80px" %)**1**|(% style="width:80px" %)**1**|(% style="width:40px" %)**1**|(% style="width:60px" %)**3**
329 329  |=(% style="width: 96px;" %)**Value**|(% style="width:84px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:40px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:44px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:121px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:52px" %)MOD|(% style="width:84px" %)[[ Calculate Flag>>||anchor="H2.4.5A0CalculateFlag"]]|(% style="width:116px" %)[[Contact Status>>||anchor="H2.4.7A0ContactStatus"]]|(% style="width:57px" %)[[Alarm>>||anchor="H2.4.6A0Alarm"]]|(% style="width:91px" %)[[Total pulse>>||anchor="H2.4.8A0Totalpulse"]]
330 330  
331 -(% border="1" style="background-color:#f2f2f2; width:490px" %)
334 +(% border="1.5" style="background-color:#ffffcc; color:green; width:490px" %)
332 332  |(% style="width:100px" %)**3**|(% style="width:50px" %)**4**|(% style="width:70px" %)**1**|(% style="width:50px" %)**3**|(% style="width:100px" %)**3**|(% style="width:80px" %)4|(% style="width:50px" %)**8 group**
333 333  |(% style="width:176px" %)[[The last open duration>>||anchor="H2.4.9A0Thelastopenduration"]]|(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.10A0Timestamp"]]|(% style="width:115px" %)Contact Status|(% style="width:92px" %)Total pulse|(% style="width:169px" %)The last open duration|(% style="width:97px" %)Time stamp|(% style="width:74px" %)...
334 334  
... ... @@ -369,6 +369,8 @@
369 369  
370 370  * (% style="color:#037691" %)**8 sets of recorded data: Contact Status, Total pulse, The last open duration ,Time stamp :**(%%) 0100000e00002663510f39,.......
371 371  
375 +
376 +
372 372  == 2.4  Payload Explanation and Sensor Interface ==
373 373  
374 374  === 2.4.1  Device ID ===
... ... @@ -513,6 +513,8 @@
513 513  * After CPN01 join NB-IoT network. The LED will be ON for 3 seconds.
514 514  * For each uplink probe, LED will be on for 500ms.
515 515  
521 +
522 +
516 516  == 2.7  Alarm Base on Timeout ==
517 517  
518 518  
... ... @@ -555,6 +555,8 @@
555 555  |(% style="width:158px" %)AT+DEBUG=0|(% style="width:196px" %)Disable debug mode to 0|(% style="width:74px" %)OK
556 556  |(% style="width:158px" %)AT+DEBUG=1|(% style="width:196px" %)Enable debug mode to 1|(% style="width:74px" %)OK
557 557  
565 +
566 +
558 558  == 2.9  Clear Flash Record ==
559 559  
560 560  
... ... @@ -569,6 +569,8 @@
569 569  Clear all stored sensor data…OK
570 570  )))
571 571  
581 +
582 +
572 572  == 2.10  Set trigger mode ==
573 573  
574 574  
... ... @@ -581,6 +581,8 @@
581 581  |(% style="width:158px" %)AT+TTRMOD=1|(% style="width:225px" %)Count and trigger from open to close (rising edge)|(% style="width:88px" %)OK
582 582  |(% style="width:158px" %)AT+TTRMOD=0|(% style="width:225px" %)Count and trigger from close to open (falling edge)|(% style="width:88px" %)OK
583 583  
595 +
596 +
584 584  == 2.11  Set the calculate flag ==
585 585  
586 586  
... ... @@ -594,6 +594,8 @@
594 594  |(% style="width:158px" %)AT+CALCFLAG=1|(% style="width:196px" %)Set the calculate flag to 1|(% style="width:74px" %)OK
595 595  |(% style="width:158px" %)AT+CALCFLAG=2|(% style="width:196px" %)Set the calculate flag to 2|(% style="width:74px" %)OK
596 596  
610 +
611 +
597 597  == 2.12 Set count number ==
598 598  
599 599  
... ... @@ -607,6 +607,8 @@
607 607  |(% style="width:158px" %)AT+SETCNT=0|(% style="width:239px" %)Set the count number to 0|(% style="width:85px" %)OK
608 608  |(% style="width:158px" %)AT+SETCNT=100|(% style="width:239px" %)Set the count number to 100|(% style="width:85px" %)OK
609 609  
625 +
626 +
610 610  == 2.13  Set the number of data to be uploaded and the recording time ==
611 611  
612 612  
... ... @@ -768,12 +768,6 @@
768 768  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string.
769 769  
770 770  
771 -== 6.3 Not able to connect to NB-IoT network and keep showing "Signal Strength:99". ==
772 -
773 -
774 -This means sensor is trying to join the NB-IoT network but fail. Please see this link for **//[[trouble shooting for signal strenght:99>>doc:Main.CSQ\:99,99.WebHome]]//**.
775 -
776 -
777 777  = 7. ​ Order Info =
778 778  
779 779  
... ... @@ -794,6 +794,7 @@
794 794  * Weight:   420g
795 795  
796 796  
808 +
797 797  = 9.  Support =
798 798  
799 799  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0