<
From version < 54.14 >
edited by Xiaoling
on 2023/04/24 09:27
To version < 54.12 >
edited by Xiaoling
on 2023/04/04 10:59
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -372,6 +372,8 @@
372 372  
373 373  * (% style="color:#037691" %)**8 sets of recorded data: Contact Status, Total pulse, The last open duration ,Time stamp :**(%%) 0100000e00002663510f39,.......
374 374  
375 +
376 +
375 375  == 2.4  Payload Explanation and Sensor Interface ==
376 376  
377 377  === 2.4.1  Device ID ===
... ... @@ -516,6 +516,8 @@
516 516  * After CPN01 join NB-IoT network. The LED will be ON for 3 seconds.
517 517  * For each uplink probe, LED will be on for 500ms.
518 518  
521 +
522 +
519 519  == 2.7  Alarm Base on Timeout ==
520 520  
521 521  
... ... @@ -558,6 +558,8 @@
558 558  |(% style="width:158px" %)AT+DEBUG=0|(% style="width:196px" %)Disable debug mode to 0|(% style="width:74px" %)OK
559 559  |(% style="width:158px" %)AT+DEBUG=1|(% style="width:196px" %)Enable debug mode to 1|(% style="width:74px" %)OK
560 560  
565 +
566 +
561 561  == 2.9  Clear Flash Record ==
562 562  
563 563  
... ... @@ -572,6 +572,8 @@
572 572  Clear all stored sensor data…OK
573 573  )))
574 574  
581 +
582 +
575 575  == 2.10  Set trigger mode ==
576 576  
577 577  
... ... @@ -584,6 +584,8 @@
584 584  |(% style="width:158px" %)AT+TTRMOD=1|(% style="width:225px" %)Count and trigger from open to close (rising edge)|(% style="width:88px" %)OK
585 585  |(% style="width:158px" %)AT+TTRMOD=0|(% style="width:225px" %)Count and trigger from close to open (falling edge)|(% style="width:88px" %)OK
586 586  
595 +
596 +
587 587  == 2.11  Set the calculate flag ==
588 588  
589 589  
... ... @@ -597,6 +597,8 @@
597 597  |(% style="width:158px" %)AT+CALCFLAG=1|(% style="width:196px" %)Set the calculate flag to 1|(% style="width:74px" %)OK
598 598  |(% style="width:158px" %)AT+CALCFLAG=2|(% style="width:196px" %)Set the calculate flag to 2|(% style="width:74px" %)OK
599 599  
610 +
611 +
600 600  == 2.12 Set count number ==
601 601  
602 602  
... ... @@ -610,6 +610,8 @@
610 610  |(% style="width:158px" %)AT+SETCNT=0|(% style="width:239px" %)Set the count number to 0|(% style="width:85px" %)OK
611 611  |(% style="width:158px" %)AT+SETCNT=100|(% style="width:239px" %)Set the count number to 100|(% style="width:85px" %)OK
612 612  
625 +
626 +
613 613  == 2.13  Set the number of data to be uploaded and the recording time ==
614 614  
615 615  
... ... @@ -771,12 +771,6 @@
771 771  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string.
772 772  
773 773  
774 -== 6.3 Not able to connect to NB-IoT network and keep showing "Signal Strength:99". ==
775 -
776 -
777 -This means sensor is trying to join the NB-IoT network but fail. Please see this link for **//[[trouble shooting for signal strenght:99>>doc:Main.CSQ\:99,99.WebHome]]//**.
778 -
779 -
780 780  = 7. ​ Order Info =
781 781  
782 782  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0