Show last authors
1 (% style="text-align:center" %)
2 [[image:1657010676286-732.png||height="452" width="452"]]
3
4
5
6
7 **Table of Contents:**
8
9 {{toc/}}
10
11
12
13
14
15
16
17
18
19
20
21
22 = 1.  Introduction =
23
24 == 1.1  What is the LG308N ==
25
26
27 (((
28 (((
29 The LG308N is an open source (% style="color:blue" %)**LoRaWAN Pico Gateway**(%%). It lets you bridge LoRa wireless network to an IP network via WiFi, Ethernet, 3G or 4G cellular network. The LoRa wireless allows users to send data and reach extremely long ranges at low data-rates.
30 )))
31
32 (((
33 The LG308N uses (% style="color:blue" %)**Semtech packet forwarder** (%%)and fully compatible with LoRaWAN protocol. It includes a (% style="color:blue" %)**SX1302 LoRa concentrator**(%%), which provides 10 programmable parallel demodulation paths.
34 )))
35
36 (((
37 LG308N has (% style="color:blue" %)**pre-configured standard LoRaWAN frequency bands**(%%) to use for different countries. User can also (% style="color:blue" %)**customized the frequency bands**(%%) to use in their own LoRa network.
38 )))
39
40 (((
41 LG308N can communicate with ABP LoRaWAN end node without LoRaWAN server. System integrator can use it to integrate with their existing IoT Service without set up own LoRaWAN server or use 3rd party LoRaWAN service.
42 )))
43 )))
44
45 (((
46
47 )))
48
49 [[image:1657010949218-224.png]]
50
51
52 == 1.2  Specifications ==
53
54
55 (% style="color:#037691" %)**Hardware System:**
56
57 (((
58 Linux Part:
59 )))
60
61 * 400Mhz ar9331 processor
62 * 64MB RAM
63 * 16MB Flash
64
65 (% style="color:#037691" %)**Interface:**
66
67 * 10M/100M RJ45 Ports x 2
68 * WiFi : 802.11 b/g/n
69 * LoRaWAN Wireless
70 * Power Input: 12 V DC, 2 A
71 * IEEE 802.3 af compliant PoE port (DC 37  ~~ 57 v)
72 * USB 2.0 host connector x 1
73 * Mini-PCI E connector x 1
74 * SX1302 + 2 x SX1250
75
76 (% style="color:#037691" %)**WiFi Spec:**
77
78 * IEEE 802.11 b/g/n
79 * Frequency Band: 2.4 ~~ 2.462GHz
80 * Tx power:
81 ** 11n tx power : mcs7/15: 11db     mcs0 : 17db
82 ** 11b tx power: 18db
83 ** 11g 54M tx power: 12db
84 ** 11g 6M tx power: 18db
85 * Wifi Sensitivity
86 ** 11g 54M : -71dbm
87 ** 11n 20M : -67dbm
88
89 (% style="color:#037691" %)**LoRa Spec:**
90
91 * Up to -142.5 dBm sensitivity with SX1250 Tx/Rx front-end
92 * 70 dB CW interferer rejection at 1 MHz offset
93 * Able to operate with negative SNR, CCR up to 9dB
94 * Emulates 49 x LoRa demodulators and 1 x (G)FSK demodulator
95 * Dual digital TX & RX radio front-end interfaces
96 * 10 programmable parallel demodulation paths
97 * Dynamic data-rate (DDR) adaptation
98 * True antenna diversity or simultaneous dual-band operation
99
100 (% style="color:#037691" %)**Cellular 4G LTE (optional):**
101
102 * Quectel: [[**EC25 LTE module**>>url:https://www.quectel.com/product/ec25minipcie.htm]]
103 * Standard Size SIM Slot
104 * 2 x 4G Sticker Antenna.
105 * Up to 150Mbps downlink and 50Mbps uplink data rates
106 * Worldwide LTE,UMTS/HSPA+ and GSM/GPRS/EDGE coverage
107 * MIMO technology meets demands for data rate and link reliability in modem wireless communication systems
108
109
110
111 == 1.3  Features ==
112
113
114 * Open Source Linux system
115 * Managed by Web GUI, SSH via LAN or WiFi
116 * Emulates 49x LoRa demodulators
117 * LoRaWAN Gateway
118 * 10 programmable parallel demodulation paths
119
120
121
122 == 1.4  Hardware System Structure ==
123
124
125 [[image:image-20221101103113-1.png]]
126
127
128 == 1.5  LG308N Applications ==
129
130
131 [[image:1657011208596-209.png]]
132
133
134 == 1.6  LED Indicators ==
135
136
137 LG308N has totally 6 LEDs, They are:
138
139 * **Power LED  **[[image:image-20220705165446-1.png||height="15" width="16"]] : This (% style="color:red" %)**LED**(%%) will be **solid on** if the device is properly powered.
140 * **HEART LED **[[image:image-20220705165446-2.png||height="16" width="15"]] : No function yet. 
141 * **SYS LED** [[image:image-20220705165446-3.png||height="16" width="15"]] :  This** LED** will shows different colors on different state:
142 ** (% style="color:red" %)**SOLID**(%%):  Device is alive with LoRaWAN server connection.
143 ** (% style="color:red" %)**BLINKING**(%%)**:**  a) Device has internet connection but no LoRaWAN Connection.  or  b) Device is in booting stage, in this stage, it will (% style="color:red" %)**BLINKING**(%%)** **for several seconds.
144 ** (% style="color:red" %)**OFF**(%%):  Device doesn't have Internet connection.
145
146 * **ETH LED** [[image:image-20220705165446-5.png||height="15" width="17"]] [[image:image-20220705165446-5.png||height="15" width="17"]]: These two LEDs show the ETH interfaces connection status.
147 * **WiFi LED** [[image:image-20220705165446-6.png||height="15" width="15"]]** **:  This LED shows the WiFi interface connection status.
148
149 (((
150 (% style="color:red" %)**Note: Above LED indication are for firmware version > LG02_LG08~-~-build-v5.3.1584002217-20200312-1639**
151 )))
152
153
154 == 1.7 Button Instruction ==
155
156
157 LG308N has a black toggle button, which is:
158
159
160 (% style="color:blue" %)**//➢ //Long press 4-5s:                     **(%%)the gateway will reload the Network and Initialize wifi configuration
161
162 **LED status: ** SYS LED will BLINKING RED Until the reload is finished.
163
164
165 (% style="color:blue" %)**➢ Long press more than 30s:    **(%%)the gateway will restart and restore factory settings.
166
167 **LED status: ** When the user releases the button, the LED will TURN OFF.
168
169
170 = 2.  Access and Configure LG308N =
171
172
173 The LG308N is configured as a WiFi Access Point by default. User can access and configure the LG308N after connecting to its WiFi network, or via its Ethernet port.
174
175
176 == 2.1  Find IP address of LG308N ==
177
178 === 2.1.1  Connect via WiFi ===
179
180
181 [[image:1657011715859-829.png]]
182
183
184 At the first boot of LG308N, it will auto generate a WiFi network called (% style="color:green" %)**//dragino-xxxxxx //**(%%)with password:
185
186
187 (% style="color:red" %)**Note: In latest version firmware, it has been password protected and the password is:  **(% style="background-color:yellow" %)**dragino+dragino**
188
189
190 [[image:1652413127647-377.png]]
191
192
193 (((
194 User can use a PC to connect to this WiFi network. The PC will get an IP address 10.130.1.xxx and the LG308N has the default IP (% style="color:green" %)**10.130.1.1**
195
196
197 )))
198
199 === 2.1.2  Connect via WAN port with DHCP IP from router ===
200
201
202 [[image:1657011966663-484.png]]
203
204
205 (((
206 Alternatively, connect the LG308N** __WAN port__** to your router and LG308N will obtain an IP address from your router. In the router's management portal, you should be able to find what IP address the router has assigned to the LG308N. You can also use this IP to connect.
207
208
209 )))
210
211 === 2.1.3  Connect via LAN port with direct connection from PC ===
212
213
214 [[image:1657012061799-674.png]]
215
216
217 (((
218 The LG308N __**LAN port**__ is configured as DHCP router by default, user can connect the PC to LAN port and set PC to DHCP mode, it will get IP from LAN port and be able to access to the device. The default IP in LAN port is 10.130.1.1
219 )))
220
221
222 === 2.1.4  Connect WiFi with DHCP IP from router ===
223
224
225 [[image:image-20220705171041-7.png]]
226
227
228 If the LG308N already connect to the router via WiFi, use can use the WiFi IP to connect to LG308N.
229
230
231 === 2.1.5  Connect via LAN port by fall back ip ===
232
233
234 The **LAN port** also has a [[fall back ip address>>path:#fallback_ip]] for access if user doesn't connect to uplink router.
235
236
237 == 2.2  Access Configure Web UI ==
238
239
240 **Web Interface**
241
242 Open a browser on the PC and type the LG308N ip address (depends on your connect method)
243
244 [[http:~~/~~/10.130.1.1/>>url:http://10.130.1.1/]] (Access via WiFi AP network)
245
246 or
247
248 http:~/~/IP_ADDRESS or http:~/~/ IP_ADDRESS:8000
249
250
251 You will see the login interface of DLOS8N as shown below.
252
253 The account details for Web Login are:
254
255 (% style="color:#4f81bd" %)**User Name: root**
256
257 (% style="color:#4f81bd" %)**Password:   dragino**
258
259
260 [[image:1652414287022-223.png]]
261
262
263 = 3.  Typical Network Setup =
264
265 == 3.1  Overview ==
266
267
268 (((
269 LG308N supports flexible network set up for different environment. This section describes the typical network topology can be set in LG308N. The typical network set up includes:
270 )))
271
272 * **WAN Port Internet Mode**
273 * **WiFi Client Mode**
274 * **WiFi AP Mode**
275 * **Cellular Mode**
276
277
278
279 == 3.2  Use WAN port to access Internet ==
280
281
282 By default, the LG308N is set to use the WAN port to connect to an upstream network. When you connect the LG308N's WAN port to an upstream router, LG308N will get an IP address from the router and have Internet access via the upstream router. The network status can be checked in the (% style="color:#4f81bd" %)**home page**:
283
284
285 [[image:1657012559318-672.png]]
286
287
288 == 3.3  Access the Internet as a WiFi Client ==
289
290
291 In the WiFi Client Mode, LG308N acts as a WiFi client and gets DHCP from an upstream router via WiFi.
292
293 (((
294 The settings for WiFi Client is under page (% style="color:#4f81bd" %)**System~-~-> WiFi ~-~-> WiFi WAN Client Settings**
295 )))
296
297 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916142159-25.png?rev=1.1||alt="image-20220916142159-25.png" height="398" width="859"]]
298
299 (((
300 In the WiFi Survey Choose the WiFi AP, and input the Passphrase then click(% style="color:blue" %)** Save & Apply**(%%) to connect.
301
302
303 )))
304
305 == 3.4  Use built-in 4G modem for internet access ==
306
307
308 If the LG308N has 3G/4G Cellular modem, user can use it as main internet connection or back up.
309
310
311 First, install the Micro SIM card as below direction
312
313 Second, Power off/ ON LG308N to let it detect the SIM card.
314
315 [[image:image-20220705171836-8.png]]
316
317
318 (((
319 The set up page is (% style="color:#4f81bd" %)**System ~-~-> Cellular**
320 )))
321
322 (((
323 While use the cellular as Backup WAN, device will use Cellular for internet connection while WAN port or WiFi is not valid and switch back to WAN port or WiFi after they recover.
324
325
326 )))
327
328 (((
329 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916141840-23.png?rev=1.1||alt="image-20220916141840-23.png" height="356" width="868"]]
330 )))
331
332
333 == 3.5  Check Internet connection ==
334
335
336 In the (% style="color:#4f81bd" %)**home**(%%) page, we can check the Internet connection.
337
338 * GREEN Tick ​​​​ [[image:1652436675869-206.png||height="14" width="15"]] : This interface has Internet connection.
339 * Yellow  Tick  [[image:1652436705761-420.png||height="15" width="15"]] : This interface has IP address but don't use it for internet connection.
340 * RED Cross    [[image:1652436787176-950.png||height="14" width="15"]] : This interface doesn't connected.
341
342 [[image:1657012821329-972.png]]
343
344
345 = 4.  Example: Configure as a LoRaWAN gateway =
346
347
348 LG308N is fully compatible with LoRaWAN protocol. It uses the legacy Semtech Packet forwarder to forward the LoRaWAN packets to server. The structure is as below.
349
350
351 (((
352 [[image:1657012860422-990.png]]
353
354
355 )))
356
357 This chapter describes how to use the LG308N to work with(TTN v3)[[ LoRaWAN Server>>url:https://www.thethingsnetwork.org/]]  ([[www.thethingsnetwork.org>>url:http://www.thethingsnetwork.org/]])
358
359
360 == 4.1  Create a gateway in TTN V3 Server ==
361
362
363 (((
364 (% style="color:blue" %)**Step 1: Get a Unique gateway ID.**
365
366
367 )))
368
369 (((
370 (((
371 Every LG308N has a unique gateway id. The ID can be found at LoRaWAN page:
372
373
374 )))
375 )))
376
377 (((
378 [[image:1657013108723-531.png]]
379
380
381 )))
382
383 The example gateway id is: (% style="color:green" %)**a840411e96744154**
384
385
386
387 (% style="color:blue" %)**Step 2: Sign up a user account in TTN server**
388
389
390 [[**https:~~/~~/account.thethingsnetwork.org/register**>>url:https://account.thethingsnetwork.org/register]]
391
392
393 [[image:1652422127479-258.png||height="346" width="738"]]
394
395
396
397 (% style="color:blue" %)**Step 3: Choose the TTNv3 Cluster Picker**
398
399
400 (((
401 [[image:1652422142236-792.png||height="356" width="737"]]
402
403
404 )))
405
406 (% style="color:red" %)**Note: Choose the cluster corresponds to a specific Gateway server address**
407
408
409 * Europe 1 (% style="color:red" %)**corresponding Gateway server address:** (% style="color:black" %)eu1.cloud.thethings.network
410 * North America 1 (% style="color:red" %)**corresponding Gateway server address: **(% style="color:black" %)nam1.cloud.thethings.network
411 * Australia 1 (% style="color:red" %)**corresponding Gateway server address: **(% style="color:black" %)au1.cloud.thethings.network
412 * Legacy V2 Console : (% style="color:red" %)**TTN v2 shuts down in December 2021**
413
414 (% style="color:blue" %)**Step 4: Create a Gateway**
415
416
417 [[image:1652422440891-514.png||height="360" width="747"]]
418
419 Click the Gateway icon and then click Add gateway.
420
421
422 Open the following page:
423
424 [[image:1652422470352-518.png||height="391" width="716"]]
425
426
427 [[image:1652422479876-297.png||height="398" width="729"]]
428
429
430 (((
431 (% style="color:red" %)**Notice: Gateway Server address must match the gateway configuration, otherwise you will have problem for End Node to join the network.**
432
433
434 )))
435
436 After creating the gateway, you can see the gateway info, as below.
437
438
439 [[image:1652422509034-682.png||height="299" width="739"]]
440
441
442 == 4.2  Configure LG308N to connect to TTN v3 ==
443
444
445 (((
446 You can now configure the LG308N to let it connect to TTN network V3.
447 )))
448
449 (((
450 Make sure your LG308N has a working Internet Connection first.
451 )))
452
453 (((
454 Choose the right server provider and click (% style="color:blue" %)**Save&Apply.**
455
456
457 )))
458
459 [[image:1652422624783-580.png||height="327" width="729"]]
460
461
462 (% style="color:red" %)**Note: The server address must match the Gateway server address you choose in TTN V3.**
463
464
465 In the home page, we can see the LoRaWAN connection is ready now.
466
467
468 [[image:image-20220916171413-2.png]]
469
470
471
472 In TTN v3 portal, we can also see the gateway is connected.
473
474
475 [[image:1652422703020-955.png||height="343" width="730"]]
476
477
478 == 4.3  Configure frequency ==
479
480
481 We also need to set the frequency plan in LG308N to match the end node we use, so to receive the LoRaWAN packets from the LoRaWAN sensor.
482
483
484 [[image:1652422737399-529.png||height="362" width="737"]]
485
486
487 In logread page, user can check the frequency actually used.
488
489 [[image:1652422763536-750.png||height="514" width="730"]]
490
491
492 == 4.4  Add a LoRaWAN End Device ==
493
494
495 (((
496 This section shows how to add a LoRaWAN End device to a LoRaWAN network and see the data from TTN web site.
497 )))
498
499 (((
500 We use [[LT-22222-L>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] IO Controller as a reference device - the setup for other LoRaWAN devices will be similar.
501 )))
502
503 [[image:1652422794767-871.png]]
504
505 (((
506 (% style="color:blue" %)**Step 1**: (% style="color:black" %)Create a Device definition in TTN v3 with the OTAA keys from the example LT-22222-L IO Controller device.
507 )))
508
509 (((
510 Three codes are required to define the device in TTN v3:
511 )))
512
513 * DEV EUI - Unique ID code for a particular device.
514 * APP EUI - ID code for an Application defined in TTN v3.
515 * APP Key - Unique key to secure communications with a particular device.
516
517 (((
518
519
520 A set of these codes are stored in each device by the manufacturer as the default codes for that particular device. Each device is shipped with a sticker with the default Device EUI as shown below.
521
522
523 )))
524
525 [[image:1652422840936-838.png]]
526
527
528 (((
529 (% style="color:red" %)**Note: You may be able to change these codes in a device by using a configuration facility on the device e.g. the LT-22222 uses a serial port access and a series of AT commands.  Changing the codes may be necessary in the case where you have to use codes assigned by a LoRa WAN server.**
530
531
532 )))
533
534 (((
535 For the TTN v3 server, you can use the codes set in the device as in the following example.
536 )))
537
538 (((
539 Select **Add Application** to open the screen below.
540 )))
541
542 [[image:1657014671459-433.png]]
543
544
545 Open the **Application **select** Add end device**
546
547
548 Start Register the end device
549
550 [[image:1652422975885-591.png||height="359" width="726"]]
551
552 (((
553 Select OTAA activation mode
554
555
556 )))
557
558 (((
559 The LoRaWAN version for your device should be provided by the manufacturer in a datasheet as LoRaWAN version or LoRaWAN specification. The most commonly used LoRaWAN versions are v1.0.2 and v1.0.3.
560 )))
561
562 [[image:1652422998005-968.png||height="352" width="744"]]
563
564 First, input the End device ID, AppEUI and DevEUI.
565
566
567 [[image:1652423022781-339.png||height="365" width="741"]]
568
569 Secondly, choose the corresponding frequency and LoRaWAN class capabilities.
570
571
572 [[image:1652423046741-467.png||height="355" width="736"]]
573
574 (((
575 Finally, Application layer settings input the corresponding AppKey. Before saving the configuration, check that the data matches the device.
576
577
578 )))
579
580 (((
581 (% style="color:blue" %)**Step 2**: (% style="color:black" %)Power on LT-22222-L device and it will automatically join the TTN network. After joining successfully, it will start to upload messages to the TTN v3. Select the Live data tab and you will see the data appearing in the panel.
582
583
584 )))
585
586 (((
587 (% style="color:red" %)**Note that it may take some time for the device data to appear in the TTN v3 display.**
588
589
590 )))
591
592 [[image:1652423277549-324.png||height="273" width="745"]]
593
594
595 = 5.  Web Configure Pages =
596
597 == 5.1  Home ==
598
599
600 Shows the system running status.
601
602
603 [[image:1657014949846-507.png]]
604
605
606 == 5.2  LoRa Settings ==
607
608 === 5.2.1  LoRa ~-~-> LoRa ===
609
610
611 (((
612 This page shows the LoRa Radio Settings. There are a set of default frequency band according to LoRaWAN protocol, and user can customized the band* as well.
613 )))
614
615 (((
616 Different LG308N hardware version can support different frequency range:
617 )))
618
619 * (% style="color:blue" %)**868**(%%): valid frequency: 863Mhz ~~ 870Mhz. for bands EU868, RU864, IN865 or KZ865.
620 * (% style="color:blue" %)**915**(%%): valid frequency: 902Mhz ~~ 928Mhz. for bands US915, AU915, AS923 or KR920
621
622 (((
623 After user choose the frequency plan, he can see the actually frequency in used by checking the page (% style="color:blue" %)**LogRead ~-~-> LoRa Log**
624
625
626 )))
627
628 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/LG308N%20-%20LoRaWAN%20Gateway%20User%20Manual/WebHome/1652422737399-529.png?rev=1.1||alt="1652422737399-529.png"]]
629
630
631 (% style="color:red" %)**Note *: [[See this instruction for how to customize frequency band>>doc:Main.How to customized LoRaWAN frequency band.WebHome]]**
632
633
634 === 5.2.2  LoRa ~-~-> ABP Decryption ===
635
636
637 The LG308N can communicate with LoRaWAN ABP End Node without the need of LoRaWAN server. It can be used in some cases such as:
638
639 * No internet connection.
640 * User wants to get data forward in gateway and forward to their server based on MQTT/HTTP, etc. (Combine ABP communication method and [[MQTT forward together>>doc:Main.MQTT Forward Instruction.WebHome]]).
641
642 (((
643
644
645 Detail of this feature: **[[Communication with ABP End Node>>doc:Main.Communicate with ABP End Node without LoRaWAN Network Server --- LG308.WebHome]]**
646
647
648 )))
649
650 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916114346-7.png?rev=1.1||alt="image-20220916114346-7.png" height="359" width="876"]]
651
652
653 == 5.3  LoRaWAN Settings ==
654
655 === 5.3.1  LoRaWAN ~-~-> LoRaWAN ===
656
657
658 This page is for the connection set up to a general LoRaWAN Network server such as: [[TTN>>url:http://www.thethingsnetwork.org/]], [[ChirpStack>>url:https://www.chirpstack.io/]] etc.
659
660
661 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916114929-8.png?rev=1.1||alt="image-20220916114929-8.png" height="707" width="860"]]
662
663
664 (% style="color:red" %)**Note:**
665
666 ~*: User can ignore the latitude and longitude settings here, LG308N will use the actually value from GPS module.
667
668 ~**: Packet filter is to drop the unwanted LoRaWAN packet, instruction see here:
669
670 **See:** **[[Filter unwanted LoRaWAN packets>>doc:Main.Filter unwanted LoRaWAN packets.WebHome]]**
671
672
673 === 5.3.2  LoRaWAN ~-~-> Amazon AWS-IoT ===
674
675
676 [[image:1652428499323-384.png||height="275" width="723"]]
677
678
679 (((
680 Please see this instruction to know more detail and demo for how to connect to **[[AWS-IoT LoRaWAN Core>>doc:Main.AWS IoT Core for LoRaWAN.WebHome]].**
681
682
683 )))
684
685 === 5.3.3  LoRaWAN ~-~-> LORIOT ===
686
687
688 (((
689 Settings to communicate to LORIOT LoRaWAN Network Server: [[https:~~/~~/www.loriot.io/>>url:https://www.loriot.io/]]
690 )))
691
692 (((
693 Instruction: **[[Notes for LORIOT>>doc:Main.Notes for LORIOT.WebHome]]**
694
695
696 )))
697
698 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916115143-9.png?rev=1.1||alt="image-20220916115143-9.png" height="316" width="864"]](% style="display:none" %)
699
700
701 == 5.4  MQTT Settings ==
702
703
704 (((
705 If end nodes works in ABP mode, user can configure LG308N to transfer the data to MQTT broker,
706 )))
707
708 (((
709 Instruction: **[[MQTT Forward Instruction>>doc:Main.MQTT Forward Instruction.WebHome]]**
710 )))
711
712
713 [[image:1652428705046-212.png||height="417" width="733"]]
714
715
716 == 5.5  System ==
717
718 === 5.5.1  System ~-~-> System Overview ===
719
720
721 Shows the system info:
722
723
724 [[image:image-20220916173046-3.png||height="613" width="868"]]
725
726
727 === 5.5.2  System ~-~-> General ( login settings) ===
728
729
730 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916134411-11.png?rev=1.1||alt="image-20220916134411-11.png" height="499" width="865"]](% style="display:none" %)
731
732
733 (((
734 (% style="color:#037691" %)**__System Password:__**
735 )))
736
737 (((
738 There are two login for DLOS8: (% style="color:#4f81bd" %)**root /dragino** (% style="color:black" %)or (% style="color:#4f81bd" %)**admin /dragino**. (% style="color:black" %)Both root and admin has the same right for WEB access. But root user has also the right to access via SSH to Linux system. admin only able to access WEB interface.
739 )))
740
741 (((
742 This page can be used to set the password for them.
743 )))
744
745 (((
746 (% style="color:#037691" %)**__Timezone: __**(%%)Set device timezone.
747 )))
748
749 (((
750 (% style="color:#037691" %)**__Port forwarding: __**(%%)Enable/Disable the HTTP and SSH access via WAN interface.
751
752
753 )))
754
755 === 5.5.3  System ~-~-> Network ===
756
757
758 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916134642-12.png?rev=1.1||alt="image-20220916134642-12.png" height="411" width="873"]]
759
760
761 (((
762 (% style="color:#037691" %)**__LAN Settings:  __**(%%)When the LG308N has the AP enable, LAN settings specify the network info for LG308N's own network.
763 )))
764
765 (((
766 (% style="color:#037691" %)__**WAN Settings: **__(%%)Setting for LG308N WAN port
767 )))
768
769 (((
770 (% style="color:#037691" %)__**WiFi Settings:  **__(%%)Setting for LG308N WiFi IP when use it as WiFi Client
771 )))
772
773
774 === 5.5.4  System ~-~-> WiFi ===
775
776
777 LG308N WiFi Settings.
778
779 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916134831-13.png?rev=1.1||alt="image-20220916134831-13.png" height="408" width="870"]]
780
781
782 === 5.5.5  System ~-~-> Cellular ===
783
784
785 While use the cellular as Backup WAN, device will use Cellular for internet connection while WAN port or WiFi is not valid and switch back to WAN port or WiFi after they recover.
786
787
788 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916135100-14.png?rev=1.1||alt="image-20220916135100-14.png" height="347" width="874"]](% style="display:none" %)
789
790
791 (% style="color:red" %)**Note *: For LG308N which doesn't have the cellular module, this page will shows Cellular not detected.**
792
793
794 === 5.5.6  System ~-~-> Network Status ===
795
796
797 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916135207-15.png?rev=1.1||alt="image-20220916135207-15.png" height="599" width="882"]]
798
799
800 === 5.5.7  System ~-~-> Remote Mgnt & Auto Provision ===
801
802
803 Auto Provision is the feature for batch configure and remote management. It can be used in below two cases:
804
805 [[image:1652429518191-846.png||height="332" width="733"]]
806
807 [[image:1652429527544-247.png||height="327" width="724"]]
808
809 [[image:1652429537849-154.png||height="339" width="722"]]
810
811
812 Please see this document for detail:
813
814 [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LG308N/Firmware/Application_Note/&file=Auto-update-feature.pdf>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LPS8/Firmware/Application_Note/&file=Auto-update-feature.pdf]]
815
816
817 R-SSH is for remote access device and management, introduction for how to use: **[[Remote Access Gateway>>doc:Main.Monitor & Remote Access Gateway.WebHome]]**
818
819 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916140017-16.png?rev=1.1||alt="image-20220916140017-16.png" height="593" width="872"]]
820
821 (% style="display:none" %) (%%)
822
823 === 5.5.8  System ~-~-> Firmware Upgrade ===
824
825
826 We keep improving the DLOS8N Linux side firmware for new features and bug fixes. Below are the links for reference.
827
828 * **Latest firmware**: [[LoRa Gateway Firmware>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LG02-OLG02/Firmware/]],
829
830 ( [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LG02-OLG02/Firmware>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LG02-OLG02/Firmware/]] )
831
832
833 * **Change Log**: [[Firmware Change Log>>url:http://www.dragino.com/downloads/downloads/LoRa_Gateway/LG02-OLG02/Firmware/ChangeLog]].
834
835 ( [[http:~~/~~/www.dragino.com/downloads/downloads/LoRa_Gateway/LG02-OLG02/Firmware/ChangeLog>>url:http://www.dragino.com/downloads/downloads/LoRa_Gateway/LG02-OLG02/Firmware/ChangeLog]] )
836
837
838 (((
839 The file named as (% style="color:green" %)**xxxxx–xxxxx-squashfs-sysupgrade.bin **(%%)is the upgrade Image. There are different methods to upgrade, as below.
840 )))
841
842 (((
843 (% style="color:green" %)**Web~-~-> System~-~-> Firmware Upgrade**
844
845
846 )))
847
848 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916140103-17.png?rev=1.1||alt="image-20220916140103-17.png" height="274" width="871"]]
849
850
851 (((
852 Select the required image and click (% style="color:blue" %)**Flash Image.**(%%) The image will be uploaded to the device, and then click (% style="color:blue" %)**Process Update** (%%)to upgrade.
853
854
855 )))
856
857 (((
858 (% style="color:red" %)**NOTE**: (%%)You normally need to (% style="color:blue" %)**//uncheck//**(%%) the (% style="color:blue" %)**Preserve Settings**(%%) checkbox when doing an upgrade to ensure that there is no conflict between the old settings and the new firmware. The new firmware will start up with its default settings.
859
860
861 )))
862
863 (((
864 The system will automatically boot into the new firmware after upgrade.
865
866
867 )))
868
869 [[image:1652429962190-224.png||height="358" width="729"]]
870
871
872 (% style="color:red" %)**NOTE***(%%): User can also upgrade firmware via Linux console
873
874 SCP the firmware to the system(% style="color:green" %)**/var**(%%)** **directory and then run
875
876 (% style="color:#4f81bd" %)**//root@OpenWrt:~~# /sbin/sysupgrade –n /var/Your_Image//**
877
878
879 (% style="color:red" %)**NOTE**(%%) : it is important to transfer the image in the /var directory, otherwise it may exceed the available flash size.
880
881
882 === 5.5.9  System ~-~-> Reboot/Reset ===
883
884
885 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916140312-18.png?rev=1.1||alt="image-20220916140312-18.png" height="274" width="873"]]
886
887 (((
888
889 )))
890
891 === 5.5.10  System ~-~-> Package Maintain ===
892
893
894 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916140421-19.png?rev=1.1||alt="image-20220916140421-19.png" height="687" width="868"]]
895
896
897 Place to show what package has installed and possible to upgrade packages.
898
899
900 == 5.6  LogRead ==
901
902 === 5.6.1  LogRead ~-~-> LoRa Log ===
903
904
905 Show the frequency for LoRa Radio and traffics.
906
907
908 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916140549-20.png?rev=1.1||alt="image-20220916140549-20.png" height="734" width="883"]]
909
910
911 === 5.6.2  LogRead ~-~-> System Log ===
912
913
914 Show the system log
915
916
917 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/DLOS8N/WebHome/image-20220916140732-21.png?rev=1.1||alt="image-20220916140732-21.png" height="706" width="867"]]
918
919
920 = 6.  More features =
921
922 == 6.1  More instructions ==
923
924
925 [[LoRaWAN Gateway Instruction>>doc:Main.WebHome]](LoRaWAN Gateway)
926
927
928 = 7.  Linux System =
929
930
931 The LG308N is based on the OpenWrt Linux system. It is open source, and users are free to configure and modify the Linux settings.
932
933
934 == 7.1  SSH Access for Linux console ==
935
936
937 User can access the Linux console via the SSH protocol. Make sure your PC and the LG308N are connected to the same network, then use a SSH tool (such as [[putty>>url:http://www.chiark.greenend.org.uk/~~sgtatham/putty/download.html]] in Windows) to access it.
938
939 IP address:  IP address of LG308N
940
941 Port:         22 (via WiFi AP mode) or 2222 (via WAN Interface)
942
943 User Name:      (% style="color:green" %)**root**
944
945 Password:         (% style="color:green" %)**dragino** (% style="color:black" %)(default)
946
947
948 After logging in, you will be in the Linux console and can enter commands as shown below.
949
950 [[image:1652431588565-830.png]]
951
952
953 The “** (% style="background-color:yellow" %)logread -f"(%%)**command can be used to debug how system runs.
954
955
956 [[image:1657070133275-283.png]]
957
958
959 == 7.2  Edit and Transfer files ==
960
961
962 (((
963 The LG308N supports the (% style="color:green" %)**SCP protocol** (% style="color:black" %)and has a built-in (% style="color:green" %)**SFTP server**. (% style="color:black" %)There are many ways to edit and transfer files using these protocols.
964 )))
965
966 (((
967 In Windows, one of the easiest methods is using the [[WinSCP>>url:https://winscp.net/eng/index.php]] utility.
968 )))
969
970 (((
971 After establishing access via WinSCP to the device, you can use an FTP style window to drag / drop files to the LG308N, or edit the files directly in the windows.
972 )))
973
974 (((
975 Screenshot is as below:
976
977
978 )))
979
980 [[image:1652431650755-450.png]]
981
982
983 == 7.3  File System ==
984
985
986 (((
987 (((
988 The LG308N has a 16MB flash and a 64MB RAM. The /var and /tmp directory are in the RAM, contents stored in /tmp and /var will be erased after reboot the device. Other directories are in the flash and will keep after reboot.
989 )))
990
991
992 (((
993 The Linux system use around 8MB ~~10MB flash size which means there is not much room for user to store data in the LG308N flash. User can use an external USB flash to extend the size for storage.
994 )))
995 )))
996
997
998 == 7.4  Package maintenance system ==
999
1000
1001 LG308N uses the OpenWrt [[**OPKG package maintenance system**>>https://oldwiki.archive.openwrt.org/doc/techref/opkg]]. There are more than 3000+ packages available in our package server for users to install for their applications. For example, if you want to add the **//iperf //** tool, you can install the related packages and configure LG308N to use **//iperf //**.
1002
1003 (((
1004 Below are some example **//opkg //** commands. For more information please refer to the [[OPKG package maintain system>>https://oldwiki.archive.openwrt.org/doc/techref/opkg]]** **([[https:~~/~~/oldwiki.archive.openwrt.org/doc/techref/opkg>>https://oldwiki.archive.openwrt.org/doc/techref/opkg]])
1005 )))
1006
1007 (((
1008 **In Linux Console run:**
1009 )))
1010
1011 (((
1012 (% style="color:green" %)**root@dragino-169d30:~~# opkg update**           (% style="color:black" %)~/~/ to get the latest packages list
1013 )))
1014
1015 (((
1016 (% style="color:green" %)**root@dragino-169d30:~~# opkg list**    (% style="color:black" %) ~/~/shows the available packages
1017 )))
1018
1019 (((
1020 (% style="color:green" %)**root@dragino-169d30:~~# opkg install iperf ** (% style="color:black" %)~/~/ install iperf
1021 )))
1022
1023 The system will automatically install the required packages as shown below.
1024
1025
1026 (((
1027 (% style="background-color:#dcdcdc" %)//root@dragino-169d30:/etc/opkg# opkg install iperf//
1028 )))
1029
1030 (((
1031 (% style="background-color:#dcdcdc" %)//Installing iperf (2.0.12-1) to root…//
1032 )))
1033
1034 (((
1035 (% style="background-color:#dcdcdc" %)//Downloading //[[(% style="background-color: rgb(220, 220, 220); background-color: rgb(220, 220, 220)" %)//http:~~/~~/downloads.openwrt.org/snapshots/packages/mips_24kc/base/iperf_2.0.12-1_mips_24kc.ipk//>>url:http://downloads.openwrt.org/snapshots/packages/mips_24kc/base/iperf_2.0.12-1_mips_24kc.ipk]]
1036 )))
1037
1038 (((
1039 (% style="background-color:#dcdcdc" %)//Installing uclibcxx (0.2.4-3) to root…//
1040 )))
1041
1042 (((
1043 (% style="background-color:#dcdcdc" %)//Downloading //[[(% style="background-color: rgb(220, 220, 220); background-color: rgb(220, 220, 220)" %)//http:~~/~~/downloads.openwrt.org/snapshots/packages/mips_24kc/base/uclibcxx_0.2.4-3_mips_24kc.ipk//>>url:http://downloads.openwrt.org/snapshots/packages/mips_24kc/base/uclibcxx_0.2.4-3_mips_24kc.ipk]]
1044 )))
1045
1046 (((
1047 (% style="background-color:#dcdcdc" %)//Configuring uclibcxx.//
1048 )))
1049
1050 (((
1051 (% style="background-color:#dcdcdc" %)//Configuring iperf.//
1052
1053
1054 )))
1055
1056 = 8.  Upgrade Linux Firmware =
1057
1058
1059 = 9.  OTA System Update =
1060
1061
1062 LG308N supports system auto update via OTA, please see **[[this URL>>url:http://wiki.dragino.com/xwiki/bin/view/OTA%20Update/]]** for the detail of this feature.
1063
1064
1065 = 10.  FAQ =
1066
1067 == 10.1  How can I configure for a customized frequency band? ==
1068
1069
1070 (((
1071 See below link for how to customize frequency band: **[[How to customized LoRaWAN frequency band>>doc:Main.How to customized LoRaWAN frequency band.WebHome]]**
1072 )))
1073
1074 (((
1075
1076 )))
1077
1078 == 10.2  Can I connect LG308N to LORIOT? ==
1079
1080
1081 Yes, the set up instruction is here: **[[Notes for LORIOT>>doc:Main.Notes for LORIOT.WebHome]]**
1082
1083
1084 == 10.3  Can I make my own firmware for the gateway, where can I find the source code? ==
1085
1086
1087 (((
1088 Yes, You can make your own firmware for the LG308N for branding purposes or to add customized applications.
1089 )))
1090
1091 (((
1092 The source code and compile instructions can be found at: [[https:~~/~~/github.com/dragino/openwrt_lede-18.06>>url:https://github.com/dragino/openwrt_lede-18.06]]
1093 )))
1094
1095
1096 == 10.4  Can I use 868Mhz version for 915Mhz bands? ==
1097
1098
1099 It is possible but the distance will be very short, you can select US915 frequency band in 868Mhz version hardware. It will work but you will see the performance is greatly decreased because the 868Mhz version has an RF filter for band 863~~870Mhz, all other frequencies will have high attenuation.
1100
1101
1102 == 10.5  Can I control the LEDs? ==
1103
1104
1105 Except the PWR LED is controlled by +3v3 power directly. All other LEDs can be controlled by developer.
1106
1107
1108 (% style="color:blue" %)**Control Globe LED:**
1109
1110 ON: echo 1 > /sys/class/leds/dragino2\:red\:wlan/brightness 
1111
1112 OFF: echo 0 > /sys/class/leds/dragino2\:red\:wlan/brightness
1113
1114
1115 (% style="color:blue" %)**Control HEART LED:**
1116
1117 First export the gpio27 and set to out
1118
1119 echo 27 > /sys/class/gpio/export
1120
1121 echo out > /sys/class/gpio/gpio27/direction
1122
1123 ON: echo 0 > /sys/class/gpio/gpio27/value
1124
1125 OFF: echo 1 > /sys/class/gpio/gpio27/value
1126
1127
1128 = 11.  Trouble Shooting =
1129
1130 == 11.1  I get kernel error when install new package, how to fix? ==
1131
1132
1133 In some cases, when installing a package with **//opkg//**, it will generate a kernel error such as below due to a mismatch I the kernel ID:
1134
1135 (% style="background-color:yellow" %)root@dragino-16c538:~~# opkg install kmod-dragino2-si3217x_3.10.49+0.2-1_ar71xx.ipk
1136
1137 (% style="background-color:yellow" %)Installing kmod-dragino2-si3217x (3.10.49+0.2-1) to root…
1138
1139 (% style="background-color:yellow" %)Collected errors:
1140
1141 (% style="background-color:yellow" %)* satisfy_dependencies_for: Cannot satisfy the following dependencies for kmod-dragino2-si3217x:
1142
1143 (% style="background-color:yellow" %)*      kernel (= 3.10.49-1-4917516478a753314254643facdf360a) *
1144
1145 (% style="background-color:yellow" %)* opkg_install_cmd: Cannot install package kmod-dragino2-si3217x.
1146
1147 (((
1148 In this case, you can use the –force-depends option to install such package as long as the actual kernel version is the same.
1149 )))
1150
1151 (% style="background-color:yellow" %)Opkg install kmod-dragino2-si3217x_3.10.49+0.2-1_ar71xx.ipk –force-depends
1152
1153
1154 == 11.2  How to recover the LG308N if the firmware crashes ==
1155
1156
1157 (((
1158 Please follow this instruction to recover your gateway:  **[[Recover Gateway>>doc:Main.How to Recover Gateway if can't access it.WebHome]]**
1159 )))
1160
1161 (((
1162
1163 )))
1164
1165 == 11.3  I configured LG308N for WiFi access and lost its IP. What to do now? ==
1166
1167
1168 [[image:1657074078183-336.png]]
1169
1170
1171 (((
1172 (((
1173 The LG308N has a fall-back IP address on its WAN port. This IP is always enabled so you can use the fall-back IP to access LG308N no matter what the WiFi IP is. The fall back IP is useful for connecting and debug the unit.
1174 )))
1175 )))
1176
1177
1178 (((
1179 (% style="color:red" %)**Note: fallback IP can be disabled in the WAN and DHCP page.**
1180 )))
1181
1182
1183 (((
1184 **Steps to connect via fall back IP:**
1185 )))
1186
1187 (((
1188 ~1. Connect PC's Ethernet port to LG01's LAN port
1189 )))
1190
1191 (((
1192 2. Configure PC's Ethernet port has IP: 172.31.255.253 and Netmask: 255.255.255.252
1193
1194
1195 )))
1196
1197 (((
1198 As below photo:
1199
1200
1201 )))
1202
1203 [[image:1652435256286-879.png]]
1204
1205
1206 3. In PC, use 172.31.255.254 to access LG308N via Web or Console.
1207
1208
1209 = 12.  Order Info =
1210
1211
1212 **//PART:(% style="color:blue" %) DLOS8N-XXX-YYY//: (%%)**(% style="color:blue" %)
1213
1214 (% style="color:blue" %)**//XXX~://**(%%)**// Frequency Band//**
1215
1216 * (% style="color:red" %)** 868**(% style="color:black" %) : valid frequency: 863Mhz ~~ 870Mhz. for bands EU868, RU864, IN865 or KZ865.
1217 * (% style="color:red" %)** 915**(% style="color:black" %):  valid frequency: 902Mhz ~~ 928Mhz. for bands US915, AU915, AS923 or KR920
1218
1219 (% style="color:#4f81bd" %)
1220
1221 (% style="color:blue" %)**//YYY~://**(%%)**// 4G Cellular Option//**
1222
1223 * (% style="color:red" %)** EC25-E**(% style="color:black" %):  EMEA, Korea, Thailand, India.
1224 * (% style="color:red" %)** EC25-A**(% style="color:black" %):  North America/ Rogers/AT&T/T-Mobile.
1225 * (% style="color:red" %)** EC25-AU**(% style="color:black" %): Latin America, New Zeland, Taiwan
1226 * (% style="color:red" %)** EC25-J**(% style="color:black" %):  Japan, DOCOMO/SoftBank/ KDDI
1227
1228 More info about valid bands, please see [[EC25-E product page>>url:https://www.quectel.com/product/ec25.htm]].
1229
1230
1231 = 13.  Packing Info =
1232
1233 (((
1234
1235
1236 **Package Includes**:
1237
1238 * LG308N or LG08 LoRa Gateway x 1
1239 * Stick Antenna for LoRa RF part. Frequency is one of 433 or 868 or 915Mhz depends the model ordered
1240 * Power Adapter: EU/AU/US type power adapter depends on country to be used
1241 * Packaging with environmental protection paper box
1242 )))
1243
1244 (((
1245
1246
1247 **Dimension and weight**:
1248 )))
1249
1250 * Device Size: 26 x 9 x 8.5 cm
1251 * Weight: 450g
1252 * Package Size: 49 x 19.5 x x 19Package Size: 4912 cm
1253 * Weight: 2.5kg
1254
1255
1256
1257 = 14.  Support =
1258
1259
1260 * Try to see if your questions already answered in the [[wiki>>doc:Main.WebHome]].
1261 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8.
1262 Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before mentioned schedule.
1263 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to: [[support@dragino.com>>url:file:///C:/Users/11315/Documents/D:/Projects/LoRa%20Product%20Line/LG308%20Picocell%20Gateway/LG308/LG308%20%25E8%25AF%25B4%25E6%2598%258E%25E4%25B9%25A6/support@dragino.com]]
1264
1265
1266
1267 = 15.  Reference =
1268
1269
1270 * Source code for LG08 LoRa Gateway: [[https:~~/~~/github.com/dragino/openwrt_lede-18.06>>url:https://github.com/dragino/openwrt_lede-18.06]]
1271
1272 * OpenWrt official Wiki: [[http:~~/~~/www.openwrt.org/>>url:http://www.openwrt.org/]]
1273
1274 * Firmware: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LG308N-OLG308N/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/LG02-OLG02/Firmware/]]
1275
1276 * Hardware Source code: [[https:~~/~~/github.com/dragino/motherboard-hardware/tree/master/LG308N>>url:https://github.com/dragino/motherboard-hardware/tree/master/LG308]]
1277
1278
1279
1280
1281
1282
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0