From version < 132.2 >
edited by Xiaoling
on 2023/05/29 10:42
To version < 132.3 >
edited by Xiaoling
on 2023/05/29 11:39
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -16,9 +16,9 @@
16 16  
17 17  
18 18  
19 -= **1. Introduction** =
19 += 1. Introduction =
20 20  
21 -== **1.1 What is LG01v2** ==
21 +== 1.1 What is LG01v2 ==
22 22  
23 23  
24 24  (((
... ... @@ -35,7 +35,7 @@
35 35  )))
36 36  
37 37  
38 -== **1.2 Specifications** ==
38 +== 1.2 Specifications ==
39 39  
40 40  
41 41  (% style="color:#037691" %)**Hardware System:**
... ... @@ -55,9 +55,11 @@
55 55  * Storage Temperature: -20 ~~ 65°C
56 56  * Power Input: 5V, 2A, DC
57 57  
58 -== **1.3 Features** ==
59 59  
60 60  
60 +== 1.3 Features ==
61 +
62 +
61 61  * Open Source Debian system
62 62  * Managed by Web GUI, SSH via WAN or WiFi
63 63  * Remote Management
... ... @@ -65,48 +65,50 @@
65 65  * LoRa Gateway
66 66  * Built-in  (% style="color:#037691" %)//**Node-Red**// (%%)local Application server
67 67  
68 -== **1.4 Block Diagram** ==
69 69  
70 70  
72 +== 1.4 Block Diagram ==
71 71  
72 -== **1.5 LED Indicators** ==
73 73  
74 74  
76 +== 1.5 LED Indicators ==
77 +
78 +
75 75  LG01-V2 has totally four LEDs, They are:
76 76  
77 77  
78 -(% style="color:blue" %)//**➢ Power LED**//(%%)//: This RED LED will be solid if the device is properly powered//
82 +(% style="color:blue" %)**➢ Power LED**(%%): This RED LED will be solid if the device is properly powered
79 79  
80 -(% style="color:blue" %)//**➢ ETH LED**//(%%)//:  This RGB LED will blink GREEN when the ETH port is connecting//
84 +(% style="color:blue" %)**➢ ETH LED**(%%):  This RGB LED will blink GREEN when the ETH port is connecting
81 81  
82 -(% style="color:blue" %)//**➢ SYS LED**//(%%)//:  This RGB LED will show different colors in different states~://
86 +(% style="color:blue" %)**➢ SYS LED**(%%):  This RGB LED will show different colors in different states:
83 83  
84 -// ✓ **SOLID GREEN:** The device is alive with a LoRaWAN server connection.//
88 + ✓ **SOLID GREEN:** The device is alive with a LoRaWAN server connection.
85 85  
86 -// ✓ **BLINKING GREEN:** a) Device has internet connection but no LoRaWAN Connection. or b) Device is in booting stage, in this stage, it will BLINKING GREEN for several seconds and then with BLINKING GREEN together//
90 + ✓ **BLINKING GREEN:** a) Device has internet connection but no LoRaWAN Connection. or b) Device is in booting stage, in this stage, it will BLINKING GREEN for several seconds and then with BLINKING GREEN together
87 87  
88 -// ✓** SOLID RED:** Device doesn't have an Internet connection.//
92 + ✓** SOLID RED:** Device doesn't have an Internet connection.
89 89  
90 -(% style="color:blue" %)//**➢ WIFI LED**//(%%)//: This LED shows the WIFI interface connection status.//
94 +(% style="color:blue" %)**➢ WIFI LED**(%%): This LED shows the WIFI interface connection status.
91 91  
92 92  
93 -== **1.6 Button Intruction** ==
97 +== 1.6 Button Intruction ==
94 94  
95 95  
96 96  LG01-V2 has a black toggle button, which is:
97 97  
98 98  
99 -(% style="color:blue" %)**// //Long press 4-5s  : **(%%)the gateway will reload the Network and Initialize wifi configuration
103 +(% style="color:blue" %)**➢ Long press 4-5s  : **(%%)the gateway will reload the Network and Initialize wifi configuration
100 100  
101 - // **LED status: ** ETH LED will BLINKIND BULE Until the reload is finished.//
105 + **LED status: ** ETH LED will BLINKIND BULE Until the reload is finished.
102 102  
103 103  
104 -(% style="color:blue" %)//**➢ **//**Long press more than 10s:**(%%)**    **//the gateway will restore the factory settings.//
108 +(% style="color:blue" %)**➢ Long press more than 10s:**(%%)**    **the gateway will restore the factory settings.
105 105  
106 - //**LED status: ** ETH LED will SOLID BULE Until the restore is finished.//
110 + **LED status: ** ETH LED will SOLID BULE Until the restore is finished.
107 107  
108 108  
109 -= **2. Quick Start** =
113 += 2. Quick Start =
110 110  
111 111  
112 112  The LG01-V2 supports network access via Ethernet or Wi-Fi connection and runs without a network.
... ... @@ -114,9 +114,9 @@
114 114  In most cases, the first thing you need to do is make the LG01-v2 accessible to the network.
115 115  
116 116  
117 -== **2.1 Connects to the network and accesses the gateway Web UI** ==
121 +== 2.1 Connects to the network and accesses the gateway Web UI ==
118 118  
119 -=== **2.1.1 connect the network.** ===
123 +=== 2.1.1 connect the network. ===
120 120  
121 121  
122 122  ==== (% style="color:blue" %)**Method 1**(%%):  Connect via Ethernet with DHCP IP from the router ====
... ... @@ -140,7 +140,7 @@
140 140  
141 141  2. Configure PC's Ethernet port has IP: 172.31.255.253 and Netmask: 255.255.255.252
142 142  
143 -Settings ~-~-> Network & Internet ~-~-> Ethernet ~-~-> Change advanced sharing options ~-~-> Double-click"Ethernet" ~-~-> Internet Protocol Version 4 (TCP/IPv4)
147 +**Settings ~-~-> Network & Internet ~-~-> Ethernet ~-~-> Change advanced sharing options ~-~-> Double-click"Ethernet" ~-~-> Internet Protocol Version 4 (TCP/IPv4)**
144 144  
145 145  
146 146  As in the below photo:
... ... @@ -150,7 +150,7 @@
150 150  
151 151  Configure computer Ethernet port steps video: **[[fallback ip.mp4>>url:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/HP0C/WebHome/fallback%20ip.mp4?rev=1.1]]**
152 152  
153 -If you still can't access the LG01v2 fallback ip, follow this connection to debug :**[[Trouble Shooting>>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20All%20Gateway%20models/LG01v2/#H10.1A0FallbackIPdoesnotwork2Chowcanuserscheck]]**
157 +If you still can't access the LG01v2 fallback ip, follow this connection to debug : **[[Trouble Shooting>>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20All%20Gateway%20models/LG01v2/#H10.1A0FallbackIPdoesnotwork2Chowcanuserscheck]]**
154 154  
155 155  3. In the PC, use IP address 172.31.255.254 to access the LG01v2 via Web or Console.
156 156  
... ... @@ -178,6 +178,7 @@
178 178  
179 179  === 2.1.2 Access Configure Web UI ===
180 180  
185 +
181 181  **Web Interface**
182 182  
183 183  Open a browser on the PC and type the LG01v2 ip address (depends on your connect method)
... ... @@ -196,51 +196,50 @@
196 196  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/HP0C/WebHome/image-20230106153501-1.png?width=894&height=367&rev=1.1||alt="image-20230106153501-1.png"]]
197 197  
198 198  
199 -= **3. Web Configure Pages** =
204 += 3. Web Configure Pages =
200 200  
201 -== **3.1 Home** ==
206 +== 3.1 Home ==
202 202  
203 203  
204 -//Shows the system running status~://
209 +Shows the system running status:
205 205  
206 206  [[image:image-20230506113531-4.png||height="430" width="818"]]
207 207  
208 208  
209 -== **3.2 Network Settings** ==
214 +== 3.2 Network Settings ==
210 210  
211 -=== **3.2.1 Network ~-~-> WiFi** ===
216 +=== 3.2.1 Network ~-~-> WiFi ===
212 212  
213 213  
214 214  [[image:image-20230506113602-5.png]]
215 215  
216 216  
217 -=== **3.4.2 Network ~-~-> System Status** ===
222 +=== 3.4.2 Network ~-~-> System Status ===
218 218  
219 219  
220 220  [[image:image-20230506113623-6.png||height="511" width="672"]]
221 221  
222 222  
228 +== 3.5 System ==
223 223  
224 -== **3.5 System** ==
230 +=== 3.5.1  System ~-~-> System Overview ===
225 225  
226 -=== **3.5.1  System ~-~-> System Overview** ===
227 227  
228 -
229 229  Shows the system info:
230 230  
231 231  [[image:image-20230506113705-7.png]]
232 232  
233 233  
234 -=== **3.5.2 System ~-~-> Backup/Restore** ===
238 +=== 3.5.2 System ~-~-> Backup/Restore ===
235 235  
236 236  
237 237  [[image:image-20230506113722-8.png||height="254" width="797"]]
238 238  
239 239  
240 -=== **3.5.3 System ~-~-> System General** ===
244 +=== 3.5.3 System ~-~-> System General ===
241 241  
242 242  
243 -In the System-> System General interface, Users can customize the configuration System Password and set Timezone.
247 +In the **System-> System General** interface, Users can customize the configuration System Password and set Timezone.
244 244  
245 245  In addition, Users can customize the FallBack IP address.
246 246  
... ... @@ -247,10 +247,10 @@
247 247  [[image:image-20230506113813-10.png||height="659" width="749"]]
248 248  
249 249  
250 -=== **3.5.4 System ~-~-> Remoteit** ===
254 +=== 3.5.4 System ~-~-> Remoteit ===
251 251  
252 252  
253 -In the System-> Remoteit interface, users can configure the gateway to be accessed remotely via Remote.it.
257 +In the **System-> Remoteit** interface, users can configure the gateway to be accessed remotely via Remote.it.
254 254  
255 255  the users can refer to this link to configure them: **[[Monitor & Remote Access Gateway>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Monitor%20%26%20Remote%20Access%20Gateway/?Remote%20Access#H2.1A0RemoteAccessviaRemote.it.]]**
256 256  
... ... @@ -257,16 +257,17 @@
257 257  [[image:image-20230506113831-11.png||height="567" width="748"]]
258 258  
259 259  
260 -=== **3.5.5 System ~-~-> Package Management** ===
264 +=== 3.5.5 System ~-~-> Package Management ===
261 261  
262 262  
263 -In the System ~-~-> Package Management interface, Users can check the current version of Core Packages.
267 +In the **System ~-~-> Package Management** interface, Users can check the current version of Core Packages.
264 264  
265 265  [[image:image-20230506114127-12.png||height="803" width="762"]]
266 266  
267 -= (% id="cke_bm_1978S" style="display:none" %)** **(%%)**4. Build in Server** =
268 268  
272 += (% id="cke_bm_1978S" style="display:none" %) (%%)4. Build in Server =
269 269  
274 +
270 270  The default factory version of LG01-V2 is installed with the built-in Applicant server: (% style="color:blue" %)**Node-Red**
271 271  
272 272  
... ... @@ -285,7 +285,7 @@
285 285   For the Node-Red, you can use the local IP address and the port is 1880 to access it.
286 286  
287 287  
288 -== **4.1 Application Server ~-~- Node-Red** ==
293 +== 4.1 Application Server ~-~- Node-Red ==
289 289  
290 290  
291 291  You can access the gateway's built-in AS server of (% style="color:blue" %)**Node-Red **(%%)via the URL((% style="background-color:yellow" %)__**//http:~/~/<hostname>:1880 or http:~/~/<local-IPV4-address>//**__(%%)) in your browser.
... ... @@ -297,23 +297,24 @@
297 297  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/HP0C/WebHome/image-20220725172124-3.png?width=843&height=610&rev=1.1||alt="image-20220725172124-3.png"]]
298 298  
299 299  
300 -= **5. How to configure the Lora Gateway** =
305 += 5. How to configure the Lora Gateway =
301 301  
302 -== **5.1 Configure and Debug LoRa wireless of LG01v2** ==
307 +== 5.1 Configure and Debug LoRa wireless of LG01v2 ==
303 303  
304 304  
305 305  First, the user needs to access the Linux console of LG01v2 via ssh
306 306  
307 -IP address:  IP address of LG01v2
312 +**IP address:  (% style="color:blue" %)IP address of LG01v2(%%)**
308 308  
309 -Port:         22
314 +**Port:  (% style="color:blue" %)22(%%)**
310 310  
311 -User Name:      (% style="color:#4f81bd" %)**root**
316 +**User Name:   (% style="color:blue" %)root(%%)**
312 312  
313 -Password:         (% style="color:#4f81bd" %)**dragino**(%%) (default)
318 +**Password:  (% style="color:blue" %)dragino(default)(%%)**
314 314  
315 315  [[image:image-20230504100722-3.png||height="228" width="908"]]
316 316  
322 +
317 317  Users can access the Lora configuration page by running the following command, then select the option **''serial port setup"**:
318 318  
319 319  (% class="box infomessage" %)
... ... @@ -361,9 +361,9 @@
361 361  )))
362 362  
363 363  
364 -== **5.2 Example: LG01v2** ==
370 +== 5.2 Example: LG01v2 ==
365 365  
366 -=== **5.2.1 Introduce for the example:** ===
372 +=== 5.2.1 Introduce for the example: ===
367 367  
368 368  
369 369  [[image:image-20221104102736-3.png||height="282" width="723"]]
... ... @@ -374,9 +374,11 @@
374 374  * **LA66 Shield + UNO + DHT11**: The UNO will get the temperature and humidity and broadcast the value via LoRa protocol.
375 375  * **LG01v2** : LG01v2 is set to listening the LoRa Channel which LA66 is broadcasting. When LG01v2 get the data from LA66, LG01v2 will plot the data in built-in IoT server.
376 376  
377 -=== **5.2.2 Set Up LA66 Shield + UNO** ===
378 378  
379 379  
385 +=== 5.2.2 Set Up LA66 Shield + UNO ===
386 +
387 +
380 380  ==== **Set up LA66 Module** ====
381 381  
382 382  
... ... @@ -456,7 +456,7 @@
456 456  [[image:image-20221108175113-9.png||height="556" width="998"]]
457 457  
458 458  
459 -=== **5.2.3 Set Up LG01v2** ===
467 +=== 5.2.3 Set Up LG01v2 ===
460 460  
461 461  
462 462  Configure LG01v2 LoRa channel parameters so it can get data from LA66 Shield
... ... @@ -481,7 +481,7 @@
481 481  )))
482 482  
483 483  
484 -=== **5.2.4 Test result** ===
492 +=== 5.2.4 Test result ===
485 485  
486 486  
487 487  After the above configuration is complete, users can send test simulation data to check whether the configuration is correct, In LA66 sheild serial console send:(% style="color:red" %)**(AT+SEND=1,hello world,2,3).**
... ... @@ -498,7 +498,7 @@
498 498  [[image:image-20221108170314-3.png]]
499 499  
500 500  
501 -=== **5.2.5 Plot data chart in LG01v2** ===
509 +=== 5.2.5 Plot data chart in LG01v2 ===
502 502  
503 503  
504 504  User can plot the temperature and humidity chat via LG01v2 built-in IoT server.
... ... @@ -515,7 +515,7 @@
515 515  [[image:image-20221108180458-11.png||height="402" width="1137"]]
516 516  
517 517  
518 -= (% style="color:inherit; font-family:inherit; font-size:29px" %)**6. How users can access LG01**(%%)**v(% style="color:inherit; font-family:inherit; font-size:29px" %)2 using serial USB(%%)** =
526 += (% style="color:inherit; font-family:inherit; font-size:29px" %)6. How users can access LG01(%%)v(% style="color:inherit; font-family:inherit; font-size:29px" %)2 using serial USB(%%) =
519 519  
520 520  
521 521  (% style="color:blue" %)**USB TTL to LG01v2  Connection:**
... ... @@ -548,15 +548,15 @@
548 548  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/HP0C/WebHome/image-20220804164747-2.png?width=594&height=622&rev=1.1||alt="image-20220804164747-2.png"]]
549 549  
550 550  
551 -= **7. OTA System Update** =
559 += 7. OTA System Update =
552 552  
553 553  
554 554  LG01v2 supports system auto update via OTA, please see **[[this URL>>url:http://wiki.dragino.com/xwiki/bin/view/OTA%20Update/]]** for the detail of this feature.
555 555  
556 556  
557 -= **8. FAQ** =
565 += 8. FAQ =
558 558  
559 -== **8.1 How does LG01v2 communicate with Lora shield (LoRa.h)** ==
567 +== 8.1 How does LG01v2 communicate with Lora shield (LoRa.h) ==
560 560  
561 561  
562 562  This example describes how to use LG01v2, LoRa Shield to set up a LoRa network,
... ... @@ -605,7 +605,7 @@
605 605  [[image:image-20221101162527-4.png]]
606 606  
607 607  
608 -== **8.2 How does LG01v2 communicate with Heltec LoRa Node** ==
616 +== 8.2 How does LG01v2 communicate with Heltec LoRa Node ==
609 609  
610 610  
611 611  This example describes how to use LG01v2 and Heltec LoRa Node to set up a LoRa network,
... ... @@ -646,15 +646,11 @@
646 646  [[image:image-20221112163119-4.png||height="808" width="560"]]
647 647  
648 648  
649 -= **9. OTA System Update** =
657 += 9. Trouble Shooting =
650 650  
651 -LG01v2 supports system auto update via OTA, please see **[[this URL>>url:http://wiki.dragino.com/xwiki/bin/view/OTA%20Update/]]** for the detail of this feature.
659 +== 9.1  Fallback IP does not work, how can users check ==
652 652  
653 653  
654 -= **10. Trouble Shooting** =
655 -
656 -== 10.1  Fallback IP does not work, how can users check ==
657 -
658 658  When the computer has completed the above fallback IP configuration,the LG01v2 Web UI is still not accessible via fallback IP.
659 659  
660 660  
... ... @@ -668,23 +668,24 @@
668 668  
669 669  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20All%20Gateway%20models/HP0C/WebHome/image-20230413170246-4.png?rev=1.1||alt="image-20230413170246-4.png"]]
670 670  
675 +
671 671  **2. Check whether the firewall is disabled**
672 672  
673 673  If the firewall is not down, this will affect access to the gateway.
674 674  
675 675  
676 -= (% style="color:inherit; font-family:inherit; font-size:29px" %)**11. Supports**(%%) =
681 += (% style="color:inherit; font-family:inherit; font-size:29px" %)10. Supports(%%) =
677 677  
678 678  
679 679  (((
680 -**//If you are experiencing issues and can't solve them, you can send mail to [[support@dragino.com>>mailto:support@dragino.com]].//**
685 +If you are experiencing issues and can't solve them, you can send mail to [[support@dragino.com>>mailto:support@dragino.com]].
681 681  )))
682 682  
683 683  (((
684 -**//With your question as detailed as possible. We will reply and help you in the shortest.//**
689 +With your question as detailed as possible. We will reply and help you in the shortest.
685 685  
686 686  
687 -= **12. Reference** =
692 += 11. Reference =
688 688  
689 689  
690 690  * Install Tago Core: Refer **Install Tago Core in LG01v2** in[[ Instruction>>doc:Main.Tago\.IO.WebHome]].
... ... @@ -693,7 +693,7 @@
693 693  
694 694  )))
695 695  
696 -= **13. Order Info** =
701 += 12. Order Info =
697 697  
698 698  
699 699  (% style="color:#0000ff" %)**LG01v2-XXX-YYY**
... ... @@ -713,7 +713,7 @@
713 713  More info about valid bands, please see [[EC25-E product page>>url:https://www.quectel.com/product/ec25.htm]].
714 714  
715 715  
716 -= **14. Manufacturer Info** =
721 += 13. Manufacturer Info =
717 717  
718 718  
719 719  **Shenzhen Dragino Technology Development co. LTD**
... ... @@ -723,7 +723,7 @@
723 723  LongCheng Street, LongGang District ; Shenzhen 518116,China
724 724  
725 725  
726 -= **15. FCC Warning** =
731 += 14. FCC Warning =
727 727  
728 728  
729 729  (((
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0