Show last authors
1 **Table of Contents:**
2
3 {{toc/}}
4
5
6
7
8
9 = 1. LoRaST v4 base Hardware =
10
11
12 Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade.
13 {{velocity}}$xwiki.ssfx.use("js/xwiki/table/table.css")
14 $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true){{/velocity}}
15
16 (% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:621.989px" %)
17 (% class="sortHeader" %)|=(% style="width: 77px;" %)Model|=(% style="width: 120px;" %)Mother Board|=(% style="width: 199px;" %)UART for AT Commands|=(% style="width: 221px;" %)UART for Upgrade Firmware
18 |(% style="width:77px" %)(((
19 PS-LB
20 )))|(% style="width:120px" %)SIB|(% style="width:199px" %)Instruction|(% style="width:221px" %)Instruction
21
22 = 2. UART for AT Commands =
23
24 == 2.1 Generate software set up for AT Commands via UART ==
25
26
27 (% start="1" style="list-style-type:decimal" %)
28 1. Use a general serial tool.
29 1. Connect PC to device's UART interface
30 1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
31 1. (((
32 The password is the last six characters of APPSKEY or PIN of box
33
34 **Example:**
35
36 APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
37
38 The password:147485
39
40 [[image:image-20230329162900-1.png||height="302" width="648"]]
41
42
43 )))
44
45 [[image:image-20221224170218-1.png||height="497" width="640"]]
46
47
48 == 2.2 UART Connection for SIB mother board ==
49
50
51 [[image:image-20221224171304-3.png||height="545" width="863"]]
52
53
54 == 2.3 UART Connection for SN50v3 base mother board ==
55
56
57 = 3. UART for Firmware Upgrade =
58
59 == 3.1 Update firmware ==
60
61 (% class="wikigeneratedid" %)
62 === 3.1.1 Update a firmware with Dragino bootloader ===
63
64
65
66
67 === 3.1.2 Update a firmware without bootloader ===
68
69 If a firmware's name doesn't have the suffix **_with_bootloader**. It means the firmware is without bootloader and user can use this method to uplink.
70
71 LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
72
73 (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
74
75 (% style="color:blue" %)**Step2**(%%): Press (% style="color:blue" %)**Reset**(%%) button, the module will then boot into program mode.
76
77 (% style="color:blue" %)**Step3**(%%): Use (% style="color:blue" %)**TremoProgrammer**(%%) to update the firmware to LoRaST v4.
78
79 (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) position. Press Reset button again and module will run the new software.
80
81
82 Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
83
84 1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
85
86 2.  Run** (% style="color:blue" %)TremoProgrammer.(%%)**
87
88 3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**(%%). (% style="color:red" %)VERY IMPORTANT: USE THIS ADDRESS FOR FIRMWARE WITHOUT BOOTLOADER
89
90 4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
91
92 [[image:image-20221224174341-4.png||height="471" width="374"]]
93
94
95
96
97
98
99 == 3.2 UART Connection for SIB mother board for Program. ==
100
101
102 Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
103
104 [[image:image-20221224174605-6.png||height="569" width="880"]]
105
106
107
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved