... ... @@ -11,24 +11,25 @@
11 11  
12 12  Below hardware use LoRaST v4 module. They supports UART Access for AT Command and Firmware Upgrade.
13 13  
14 -
15 15  {{velocity}}
16 16  $xwiki.ssfx.use("js/xwiki/table/table.css")
17 17  $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
18 18  {{/velocity}}
19 19  
20 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f2f2f2; width:955px" %)
21 -(% class="sortHeader" %)|=(% style="width: 269px; background-color: rgb(217, 226, 243);" %)Models|=(% style="width: 158px; background-color: rgb(217, 226, 243);" %)**Mother Board**|=(% style="width: 286px; background-color: rgb(217, 226, 243);" %)**UART for AT Commands**|=(% style="width: 267px;background-color:#D9E2F3" %)**UART for Upgrade Firmware**
22 -|(% style="width:269px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:158px" %)SIB|(% style="width:286px" %)Instruction|(% style="width:267px" %)Instruction
23 -|(% style="width:269px" %)(((
19 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:829px" %)
20 +|(% style="background-color:#d9e2f3; color:#0070c0; width:290px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:116px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:248px" %)**UART for Upgrade Firmware**
21 +|(% style="width:290px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:172px" %)SIB|(% style="width:116px" %)Instruction|(% style="width:248px" %)Instruction
22 +|(% style="width:290px" %)(((
24 24  SN50v3, S31-LB, S31B-LB,
25 25  
26 26  D20-LB.D20S-LB, D21-LB, D22-LB
27 -)))|(% style="width:158px" %)SN50v3|(% style="width:286px" %) |(% style="width:267px" %)
28 -|(% style="width:269px" %)LHT65N|(% style="width:158px" %)LHT65N|(% style="width:286px" %) |(% style="width:267px" %)
26 +)))|(% style="width:172px" %)SN50v3|(% style="width:116px" %) |(% style="width:248px" %)
27 +|(% style="width:290px" %)LHT65N|(% style="width:172px" %)LHT65N|(% style="width:116px" %) |(% style="width:248px" %)
28 +|(% style="width:290px" %) |(% style="width:172px" %) |(% style="width:116px" %) |(% style="width:248px" %)
29 29  
30 30  
31 31  
32 +
32 32  = 2. UART for AT Commands =
33 33  
34 34  == 2.1 Generate software set up for AT Commands via UART ==
... ... @@ -43,7 +43,6 @@
43 43  (((
44 44  4. The password is the last six characters of APPSKEY or PIN of box
45 45  
46 -
47 47  **Example:**
48 48  
49 49  APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
... ... @@ -66,7 +66,6 @@
66 66  
67 67  == 2.3 UART Connection for SN50v3 base mother board ==
68 68  
69 -
70 70  [[image:image-20230515102801-1.png]]
71 71  
72 72  
... ... @@ -87,7 +87,6 @@
87 87  
88 88  === 3.1.2 How can i know if my device already have bootloader? ===
89 89  
90 -
91 91  If a device has a bootloader. it will output bootloader info to UART when boot. As below:
92 92  
93 93  [[image:image-20230514150410-1.png||height="398" width="815"]]
... ... @@ -95,13 +95,12 @@
95 95  
96 96  === 3.1.3 How to upload bootloader to device? ===
97 97  
98 -
99 99  If your is LoRa ST v4 base hardware and doesn't have bootloader. You can upload a bootloader to it.
100 100  
101 101  **[[Downlink Link for OTA bootloader>>https://www.dropbox.com/sh/g4cp2lm85ovr8hu/AADX-4aEE-7SuKQAKTWrgKHIa?dl=0]].**
102 102  
103 103  
104 -(% style="color:blue" %)**Update a firmware via TremoProgrammer:**
101 +**Update a firmware via TremoProgrammer:**
105 105  
106 106  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
107 107  
... ... @@ -127,11 +127,11 @@
127 127  [[image:image-20230515171651-1.png]]
128 128  
129 129  
127 +
130 130  == 3.2 Update Firmware (Assume the device already have a bootloader) ==
131 131  
132 132  === 3.2.1 Update a firmware via Dragino Sensor Manager Utility.exe ===
133 133  
134 -
135 135  ~1. Download **[[OTA Tool>>https://www.dropbox.com/sh/bqepfzvusv6ig8e/AACKB4J9pdY1I7s5kcKfCUGHa?dl=0]]**
136 136  
137 137  2. Use below schedule to update:
... ... @@ -147,13 +147,11 @@
147 147  
148 148  == 4.1 How to recover if upgrade wrong file to bootloader? ==
149 149  
150 -
151 151  You can just upload the bootloader again.
152 152  
153 153  
154 154  == 4.2 How to recover if upgrade wrong firmware via Dragino Sensor Manager Utility.exe? ==
155 155  
156 -
157 157  The UART upgrade via Dragino Sensor Manager Utility.exe is base on Dragino Bootloader. So if you are able to upgrade some file via this tool. It means the device has bootloder.
158 158  
159 159  
... ... @@ -168,30 +168,26 @@
168 168  
169 169  == 4.3 How to use TremoProgrammer to update firmware if there is bootloader in the device? ==
170 170  
171 -
172 172  Make sure your device already bootloader while use this update. Otherwise device won't be able to boot ( can be solve by upload a bootloader to the device).
173 173  
174 174  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
175 175  
176 - (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
170 + **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially.
177 177  
178 - (% style="color:blue" %) **Step2**(%%): Press (% style="color:blue" %)**Reset**(%%) button, the module will then boot into program mode.
172 + **Step2**: Press **Reset** button, the module will then boot into program mode.
179 179  
180 - (% style="color:blue" %)**Step3**(%%): Use (% style="color:blue" %)**TremoProgrammer**(%%) to update the firmware to LoRaST v4.
174 + **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4.
181 181  
182 - (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) position. Press Reset button again and module will run the new software.
176 + **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software.
183 183  
178 +Below is the method for how to update via **TremoProgrammer:**
184 184  
185 -Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
186 -
187 187  1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
188 188  
189 -2.  Run(% style="color:blue" %)** TremoProgrammer.**
182 +2.  Run** TremoProgrammer.**
190 190  
191 -3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**. (% style="color:red" %)**VERY IMPORTANT for this address**.
184 +3.  Choose software and set the address to **0x0800D000**. (% class="mark" %)VERY IMPORTANT for this address(%%).
192 192  
193 -4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
186 +4. Rember to set BOOT Switch to **FLASH** after update
194 194  
195 195  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/WebHome/image-20221224174341-4.png?width=374&height=471&rev=1.1||alt="image-20221224174341-4.png" height="471" width="374"]]
196 -