<
From version < 47.7 >
edited by Xiaoling
on 2023/06/01 16:02
To version < 47.5 >
edited by Xiaoling
on 2023/06/01 15:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -16,17 +16,20 @@
16 16  $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
17 17  {{/velocity}}
18 18  
19 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:949px" %)
20 -|(% style="background-color:#d9e2f3;width:290px" %)**Models**|(% style="background-color:#d9e2f3; width:172px" %)**Mother Board**|(% style="background-color:#d9e2f3; width:233px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:249px" %)**UART for Upgrade Firmware**
21 -|(% style="width:290px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:172px" %)SIB|(% style="width:233px" %)Instruction|(% style="width:249px" %)Instruction
19 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:829px" %)
20 +|(% style="background-color:#d9e2f3; color:#0070c0; width:290px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:116px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:248px" %)**UART for Upgrade Firmware**
21 +|(% style="width:290px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:172px" %)SIB|(% style="width:116px" %)Instruction|(% style="width:248px" %)Instruction
22 22  |(% style="width:290px" %)(((
23 23  SN50v3, S31-LB, S31B-LB,
24 24  
25 25  D20-LB.D20S-LB, D21-LB, D22-LB
26 -)))|(% style="width:172px" %)SN50v3|(% style="width:233px" %) |(% style="width:249px" %)
27 -|(% style="width:290px" %)LHT65N|(% style="width:172px" %)LHT65N|(% style="width:233px" %) |(% style="width:249px" %)
26 +)))|(% style="width:172px" %)SN50v3|(% style="width:116px" %) |(% style="width:248px" %)
27 +|(% style="width:290px" %)LHT65N|(% style="width:172px" %)LHT65N|(% style="width:116px" %) |(% style="width:248px" %)
28 +|(% style="width:290px" %) |(% style="width:172px" %) |(% style="width:116px" %) |(% style="width:248px" %)
28 28  
29 29  
31 +
32 +
30 30  = 2. UART for AT Commands =
31 31  
32 32  == 2.1 Generate software set up for AT Commands via UART ==
... ... @@ -41,7 +41,6 @@
41 41  (((
42 42  4. The password is the last six characters of APPSKEY or PIN of box
43 43  
44 -
45 45  **Example:**
46 46  
47 47  APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
... ... @@ -64,7 +64,6 @@
64 64  
65 65  == 2.3 UART Connection for SN50v3 base mother board ==
66 66  
67 -
68 68  [[image:image-20230515102801-1.png]]
69 69  
70 70  
... ... @@ -85,7 +85,6 @@
85 85  
86 86  === 3.1.2 How can i know if my device already have bootloader? ===
87 87  
88 -
89 89  If a device has a bootloader. it will output bootloader info to UART when boot. As below:
90 90  
91 91  [[image:image-20230514150410-1.png||height="398" width="815"]]
... ... @@ -93,13 +93,12 @@
93 93  
94 94  === 3.1.3 How to upload bootloader to device? ===
95 95  
96 -
97 97  If your is LoRa ST v4 base hardware and doesn't have bootloader. You can upload a bootloader to it.
98 98  
99 99  **[[Downlink Link for OTA bootloader>>https://www.dropbox.com/sh/g4cp2lm85ovr8hu/AADX-4aEE-7SuKQAKTWrgKHIa?dl=0]].**
100 100  
101 101  
102 -(% style="color:blue" %)**Update a firmware via TremoProgrammer:**
101 +**Update a firmware via TremoProgrammer:**
103 103  
104 104  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
105 105  
... ... @@ -125,11 +125,11 @@
125 125  [[image:image-20230515171651-1.png]]
126 126  
127 127  
127 +
128 128  == 3.2 Update Firmware (Assume the device already have a bootloader) ==
129 129  
130 130  === 3.2.1 Update a firmware via Dragino Sensor Manager Utility.exe ===
131 131  
132 -
133 133  ~1. Download **[[OTA Tool>>https://www.dropbox.com/sh/bqepfzvusv6ig8e/AACKB4J9pdY1I7s5kcKfCUGHa?dl=0]]**
134 134  
135 135  2. Use below schedule to update:
... ... @@ -145,13 +145,11 @@
145 145  
146 146  == 4.1 How to recover if upgrade wrong file to bootloader? ==
147 147  
148 -
149 149  You can just upload the bootloader again.
150 150  
151 151  
152 152  == 4.2 How to recover if upgrade wrong firmware via Dragino Sensor Manager Utility.exe? ==
153 153  
154 -
155 155  The UART upgrade via Dragino Sensor Manager Utility.exe is base on Dragino Bootloader. So if you are able to upgrade some file via this tool. It means the device has bootloder.
156 156  
157 157  
... ... @@ -166,30 +166,26 @@
166 166  
167 167  == 4.3 How to use TremoProgrammer to update firmware if there is bootloader in the device? ==
168 168  
169 -
170 170  Make sure your device already bootloader while use this update. Otherwise device won't be able to boot ( can be solve by upload a bootloader to the device).
171 171  
172 172  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
173 173  
174 - (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
170 + **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially.
175 175  
176 - (% style="color:blue" %) **Step2**(%%): Press (% style="color:blue" %)**Reset**(%%) button, the module will then boot into program mode.
172 + **Step2**: Press **Reset** button, the module will then boot into program mode.
177 177  
178 - (% style="color:blue" %)**Step3**(%%): Use (% style="color:blue" %)**TremoProgrammer**(%%) to update the firmware to LoRaST v4.
174 + **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4.
179 179  
180 - (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) position. Press Reset button again and module will run the new software.
176 + **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software.
181 181  
178 +Below is the method for how to update via **TremoProgrammer:**
182 182  
183 -Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
184 -
185 185  1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
186 186  
187 -2.  Run(% style="color:blue" %)** TremoProgrammer.**
182 +2.  Run** TremoProgrammer.**
188 188  
189 -3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**. (% style="color:red" %)**VERY IMPORTANT for this address**.
184 +3.  Choose software and set the address to **0x0800D000**. (% class="mark" %)VERY IMPORTANT for this address(%%).
190 190  
191 -4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
186 +4. Rember to set BOOT Switch to **FLASH** after update
192 192  
193 193  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/WebHome/image-20221224174341-4.png?width=374&height=471&rev=1.1||alt="image-20221224174341-4.png" height="471" width="374"]]
194 -
195 -
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0