From version < 47.5 >
edited by Xiaoling
on 2023/06/01 15:53
To version < 47.10 >
edited by Xiaoling
on 2023/06/01 16:09
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -11,25 +11,24 @@
11 11  
12 12  Below hardware use LoRaST v4 module. They supports UART Access for AT Command and Firmware Upgrade.
13 13  
14 +
14 14  {{velocity}}
15 15  $xwiki.ssfx.use("js/xwiki/table/table.css")
16 16  $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
17 17  {{/velocity}}
18 18  
19 -(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="width:829px" %)
20 -|(% style="background-color:#d9e2f3; color:#0070c0; width:290px" %)**Models**|(% style="background-color:#d9e2f3; color:#0070c0; width:172px" %)**Mother Board**|(% style="background-color:#d9e2f3; color:#0070c0; width:116px" %)**UART for AT Commands**|(% style="background-color:#d9e2f3; color:#0070c0; width:248px" %)**UART for Upgrade Firmware**
21 -|(% style="width:290px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:172px" %)SIB|(% style="width:116px" %)Instruction|(% style="width:248px" %)Instruction
22 -|(% style="width:290px" %)(((
20 +(% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f2f2f2; width:869px" %)
21 +(% class="sortHeader" %)|=(% style="width: 269px; background-color: rgb(217, 226, 243);" %)Models|=(% style="width: 158px; background-color: rgb(217, 226, 243);" %)**Mother Board**|=(% style="width: 214px; background-color: rgb(217, 226, 243);" %)**UART for AT Commands**|=(% style="width: 226px; background-color: rgb(217, 226, 243);" %)**UART for Upgrade Firmware**
22 +|(% style="width:269px" %)PS-LB, PS-LB-NA, SDI12-LB|(% style="width:158px" %)SIB|(% style="width:214px" %)Instruction|(% style="width:226px" %)Instruction
23 +|(% style="width:269px" %)(((
23 23  SN50v3, S31-LB, S31B-LB,
24 24  
25 25  D20-LB.D20S-LB, D21-LB, D22-LB
26 -)))|(% style="width:172px" %)SN50v3|(% style="width:116px" %) |(% style="width:248px" %)
27 -|(% style="width:290px" %)LHT65N|(% style="width:172px" %)LHT65N|(% style="width:116px" %) |(% style="width:248px" %)
28 -|(% style="width:290px" %) |(% style="width:172px" %) |(% style="width:116px" %) |(% style="width:248px" %)
27 +)))|(% style="width:158px" %)SN50v3|(% style="width:214px" %) |(% style="width:226px" %)
28 +|(% style="width:269px" %)LHT65N|(% style="width:158px" %)LHT65N|(% style="width:214px" %) |(% style="width:226px" %)
29 29  
30 30  
31 31  
32 -
33 33  = 2. UART for AT Commands =
34 34  
35 35  == 2.1 Generate software set up for AT Commands via UART ==
... ... @@ -44,6 +44,7 @@
44 44  (((
45 45  4. The password is the last six characters of APPSKEY or PIN of box
46 46  
46 +
47 47  **Example:**
48 48  
49 49  APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
... ... @@ -66,6 +66,7 @@
66 66  
67 67  == 2.3 UART Connection for SN50v3 base mother board ==
68 68  
69 +
69 69  [[image:image-20230515102801-1.png]]
70 70  
71 71  
... ... @@ -86,6 +86,7 @@
86 86  
87 87  === 3.1.2 How can i know if my device already have bootloader? ===
88 88  
90 +
89 89  If a device has a bootloader. it will output bootloader info to UART when boot. As below:
90 90  
91 91  [[image:image-20230514150410-1.png||height="398" width="815"]]
... ... @@ -93,12 +93,13 @@
93 93  
94 94  === 3.1.3 How to upload bootloader to device? ===
95 95  
98 +
96 96  If your is LoRa ST v4 base hardware and doesn't have bootloader. You can upload a bootloader to it.
97 97  
98 98  **[[Downlink Link for OTA bootloader>>https://www.dropbox.com/sh/g4cp2lm85ovr8hu/AADX-4aEE-7SuKQAKTWrgKHIa?dl=0]].**
99 99  
100 100  
101 -**Update a firmware via TremoProgrammer:**
104 +(% style="color:blue" %)**Update a firmware via TremoProgrammer:**
102 102  
103 103  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
104 104  
... ... @@ -124,11 +124,11 @@
124 124  [[image:image-20230515171651-1.png]]
125 125  
126 126  
127 -
128 128  == 3.2 Update Firmware (Assume the device already have a bootloader) ==
129 129  
130 130  === 3.2.1 Update a firmware via Dragino Sensor Manager Utility.exe ===
131 131  
134 +
132 132  ~1. Download **[[OTA Tool>>https://www.dropbox.com/sh/bqepfzvusv6ig8e/AACKB4J9pdY1I7s5kcKfCUGHa?dl=0]]**
133 133  
134 134  2. Use below schedule to update:
... ... @@ -144,11 +144,13 @@
144 144  
145 145  == 4.1 How to recover if upgrade wrong file to bootloader? ==
146 146  
150 +
147 147  You can just upload the bootloader again.
148 148  
149 149  
150 150  == 4.2 How to recover if upgrade wrong firmware via Dragino Sensor Manager Utility.exe? ==
151 151  
156 +
152 152  The UART upgrade via Dragino Sensor Manager Utility.exe is base on Dragino Bootloader. So if you are able to upgrade some file via this tool. It means the device has bootloder.
153 153  
154 154  
... ... @@ -163,26 +163,30 @@
163 163  
164 164  == 4.3 How to use TremoProgrammer to update firmware if there is bootloader in the device? ==
165 165  
171 +
166 166  Make sure your device already bootloader while use this update. Otherwise device won't be able to boot ( can be solve by upload a bootloader to the device).
167 167  
168 168  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
169 169  
170 - **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially.
176 + (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
171 171  
172 - **Step2**: Press **Reset** button, the module will then boot into program mode.
178 + (% style="color:blue" %) **Step2**(%%): Press (% style="color:blue" %)**Reset**(%%) button, the module will then boot into program mode.
173 173  
174 - **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4.
180 + (% style="color:blue" %)**Step3**(%%): Use (% style="color:blue" %)**TremoProgrammer**(%%) to update the firmware to LoRaST v4.
175 175  
176 - **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software.
182 + (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) position. Press Reset button again and module will run the new software.
177 177  
178 -Below is the method for how to update via **TremoProgrammer:**
179 179  
185 +Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
186 +
180 180  1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
181 181  
182 -2.  Run** TremoProgrammer.**
189 +2.  Run(% style="color:blue" %)** TremoProgrammer.**
183 183  
184 -3.  Choose software and set the address to **0x0800D000**. (% class="mark" %)VERY IMPORTANT for this address(%%).
191 +3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**. (% style="color:red" %)**VERY IMPORTANT for this address**.
185 185  
186 -4. Rember to set BOOT Switch to **FLASH** after update
193 +4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
187 187  
188 188  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/WebHome/image-20221224174341-4.png?width=374&height=471&rev=1.1||alt="image-20221224174341-4.png" height="471" width="374"]]
196 +
197 +
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0