From version < 42.1 >
edited by Edwin Chen
on 2023/05/20 10:25
To version < 30.1 >
edited by Edwin Chen
on 2023/05/14 16:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -63,7 +63,6 @@
63 63  
64 64  == 2.3 UART Connection for SN50v3 base mother board ==
65 65  
66 -[[image:image-20230515102801-1.png]]
67 67  
68 68  
69 69  = 3. UART for Firmware Upgrade =
... ... @@ -75,10 +75,9 @@
75 75  
76 76  Dragino Bootloader is a customizer made bootloader which support below features:
77 77  
78 -* OTA Update via LoRa
79 -* OTA Batch update configure via LoRa
77 +* OTA Update via LoRa or BLE
78 +* OTA Batch update configure via LoRa or BLE
80 80  
81 -All Dragino End Devices base on LoRa ST v4 supports Dragino Bootloader.
82 82  
83 83  
84 84  === 3.1.2 How can i know if my device already have bootloader? ===
... ... @@ -90,13 +90,19 @@
90 90  
91 91  === 3.1.3 How to upload bootloader to device? ===
92 92  
93 -If your is LoRa ST v4 base hardware and doesn't have bootloader. You can upload a bootloader to it.
94 94  
95 -**[[Downlink Link for OTA bootloader>>https://www.dropbox.com/sh/g4cp2lm85ovr8hu/AADX-4aEE-7SuKQAKTWrgKHIa?dl=0]].**
96 96  
93 +== 3.2 Update Firmware (Assume the device already have a bootloader) ==
97 97  
98 -**Update a firmware via TremoProgrammer:**
95 +=== 3.2.1 Update a firmware via Dragino bootloader ===
99 99  
97 +
98 +
99 +
100 +=== 3.2.2 Update a firmware via TremoProgrammer ===
101 +
102 +Make sure your device already bootloader while use this update. Other device won't be able to boot ( can be solve by upload a bootloader to the device).
103 +
100 100  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
101 101  
102 102   (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
... ... @@ -110,79 +110,15 @@
110 110  
111 111  Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
112 112  
113 -1.  **TremoProgrammer** download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
117 +1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
114 114  
115 115  2.  Run** (% style="color:blue" %)TremoProgrammer.(%%)**
116 116  
117 -3.  Choose software and set the address to (% style="color:blue" %)**0x08000000**(%%).
121 +3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**(%%). (% style="color:red" %)VERY IMPORTANT: USE THIS ADDRESS FOR FIRMWARE WITHOUT BOOTLOADER
118 118  
119 -4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update finish. And you should be about to see Bootloader info in output after update
123 +4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
120 120  
121 -[[image:image-20230515171651-1.png]]
125 +[[image:image-20221224174341-4.png||height="471" width="374"]]
122 122  
123 123  
124 -
125 -== 3.2 Update Firmware (Assume the device already have a bootloader) ==
126 -
127 -=== 3.2.1 Update a firmware via Dragino Sensor Manager Utility.exe ===
128 -
129 -~1. Download **[[OTA Tool>>https://www.dropbox.com/sh/bqepfzvusv6ig8e/AACKB4J9pdY1I7s5kcKfCUGHa?dl=0]]**
130 -
131 -2. Use below schedule to update:
132 -
133 -[[image:image-20230520100249-1.png||height="483" width="805"]]
134 -
135 -[[image:image-20230520100405-3.png||height="295" width="804"]]
136 -
137 -
138 -[[image:image-20230520100541-5.png||height="535" width="799"]]
139 -
140 -
141 -= 4. FAQ =
142 -
143 -== 4.1 How to recover if upgrade wrong file to bootloader? ==
144 -
145 -You can just upload the bootloader again.
146 -
147 -
148 -== 4.2 How to recover if upgrade wrong firmware via Dragino Sensor Manager Utility.exe? ==
149 -
150 -The UART upgrade via Dragino Sensor Manager Utility.exe is base on Dragino Bootloader. So if you are able to upgrade some file via this tool. It means the device has bootloder.
151 -
152 -
153 -The upgrade via Dragino Sensor Manager Utility is base on firmware level and won't effect the bootloader. If you upgrade a wrong firmware file, you can try below:
154 -
155 -~1. UART upgrade via Dragino Sensor Manager Utility again to the correct version. The password should use the AT PIN for the wrong firmware.  (This method is not 100% work, depends which wrong firmware you have upgraded)
156 -
157 -2. Use **TremoProgrammer **to update firmware.
158 -
159 -3. Use **[[OTA update>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20OTA%20Update%20for%20Sensors/]]**, this is base on Bootloader so it will work. Make you choose the correct frequency band (base on the firmware version in the sensor or use EU868 which is the default setting.)
160 -
161 -
162 -== 4.3 How to use TremoProgrammer to update firmware if there is bootloader in the device? ==
163 -
164 -Make sure your device already bootloader while use this update. Otherwise device won't be able to boot ( can be solve by upload a bootloader to the device).
165 -
166 -LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
167 -
168 - **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially.
169 -
170 - **Step2**: Press **Reset** button, the module will then boot into program mode.
171 -
172 - **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4.
173 -
174 - **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software.
175 -
176 -Below is the method for how to update via **TremoProgrammer:**
177 -
178 -1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
179 -
180 -2.  Run** TremoProgrammer.**
181 -
182 -3.  Choose software and set the address to **0x0800D000**. (% class="mark" %)VERY IMPORTANT for this address(%%).
183 -
184 -4. Rember to set BOOT Switch to **FLASH** after update
185 -
186 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/WebHome/image-20221224174341-4.png?width=374&height=471&rev=1.1||alt="image-20221224174341-4.png" height="471" width="374"]]
187 -
188 188  
image-20230515102801-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -812.6 KB
Content
image-20230515171651-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -20.6 KB
Content
image-20230520100249-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -38.5 KB
Content
image-20230520100330-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -28.0 KB
Content
image-20230520100405-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -58.3 KB
Content
image-20230520100449-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -107.8 KB
Content
image-20230520100541-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -92.3 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0