<
From version < 4.1 >
edited by Edwin Chen
on 2022/12/24 16:56
To version < 18.1 >
edited by Bei Jinggeng
on 2023/03/29 16:29
>
Change comment: Uploaded new attachment "image-20230329162900-1.png", version {1}

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Bei
Content
... ... @@ -1,9 +1,87 @@
1 -= LoRaST v4 base Hardware =
1 +**Table of Contents:**
2 2  
3 +{{toc/}}
4 +
5 +
6 +
7 +
8 +
9 += 1. LoRaST v4 base Hardware =
10 +
11 +
3 3  Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade.
13 +{{velocity}}$xwiki.ssfx.use("js/xwiki/table/table.css")
14 +$xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true){{/velocity}}
4 4  
5 -(% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:770px" %)
6 -(% class="sortHeader" %)|=(% style="width: 180px;" %)Model|=(% style="width: 135px;" %)Mother Board|=(% style="width: 199px;" %)UART for AT Commands|=(% style="width: 230px;" %)UART for Upgrade Firmware
7 -|(% style="width:180px" %)(((
16 +(% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:621.989px" %)
17 +(% class="sortHeader" %)|=(% style="width: 77px;" %)Model|=(% style="width: 120px;" %)Mother Board|=(% style="width: 199px;" %)UART for AT Commands|=(% style="width: 221px;" %)UART for Upgrade Firmware
18 +|(% style="width:77px" %)(((
8 8  **PS-LB **
9 -)))|(% style="width:135px" %)SIB|(% style="width:199px" %)Instruction|(% style="width:230px" %)Instruction
20 +)))|(% style="width:120px" %)SIB|(% style="width:199px" %)Instruction|(% style="width:221px" %)Instruction
21 +
22 += 2. UART for AT Commands =
23 +
24 +== 2.1 Generate software set up for AT Commands via UART ==
25 +
26 +
27 +(% start="1" style="list-style-type:decimal" %)
28 +1. Use a general serial tool.
29 +1. Connect PC to device's UART interface
30 +1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
31 +1. (((
32 +The password is the last six characters of APPSKEY
33 +
34 +Example:
35 +
36 +APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
37 +
38 +The password:147485
39 +)))
40 +
41 +[[image:image-20221224170218-1.png||height="497" width="640"]]
42 +
43 +
44 +== 2.2 UART Connection for SIB mother board ==
45 +
46 +
47 +[[image:image-20221224171304-3.png||height="545" width="863"]]
48 +
49 +
50 += 3. UART for Firmware Upgrade =
51 +
52 +== 3.1 General Instruction for UART update firmware ==
53 +
54 +
55 +LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
56 +
57 + (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
58 +
59 + (% style="color:blue" %)**Step2**(%%): Press (% style="color:blue" %)**Reset**(%%) button, the module will then boot into program mode.
60 +
61 + (% style="color:blue" %)**Step3**(%%): Use (% style="color:blue" %)**TremoProgrammer**(%%) to update the firmware to LoRaST v4.
62 +
63 + (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) position. Press Reset button again and module will run the new software.
64 +
65 +
66 +Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
67 +
68 +1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
69 +
70 +2.  Run** (% style="color:blue" %)TremoProgrammer.(%%)**
71 +
72 +3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**
73 +
74 +4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
75 +
76 +[[image:image-20221224174341-4.png||height="471" width="374"]]
77 +
78 +
79 +== 3.2 UART Connection for SIB mother board for Program. ==
80 +
81 +
82 +Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
83 +
84 +[[image:image-20221224174605-6.png||height="569" width="880"]]
85 +
86 +
87 +
image-20221224170218-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +60.4 KB
Content
image-20221224171231-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
image-20221224171304-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +1.4 MB
Content
image-20221224174341-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +22.7 KB
Content
image-20221224174529-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +1.6 MB
Content
image-20221224174605-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +1.5 MB
Content
image-20230329162900-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +217.0 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0