... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -19,25 +19,17 @@
19 19  **PS-LB **
20 20  )))|(% style="width:120px" %)SIB|(% style="width:199px" %)Instruction|(% style="width:221px" %)Instruction
21 21  
22 +
23 +
22 22  = 2. UART for AT Commands =
23 23  
24 24  == 2.1 Generate software set up for AT Commands via UART ==
25 25  
26 26  
27 -(% start="1" style="list-style-type:decimal" %)
28 28  1. Use a general serial tool.
29 29  1. Connect PC to device's UART interface
30 30  1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
31 -1. (((
32 -The password is the last six characters of APPSKEY
33 33  
34 -Example:
35 -
36 -APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
37 -
38 -The password:147485
39 -)))
40 -
41 41  [[image:image-20221224170218-1.png||height="497" width="640"]]
42 42  
43 43  
... ... @@ -47,6 +47,7 @@
47 47  [[image:image-20221224171304-3.png||height="545" width="863"]]
48 48  
49 49  
42 +
50 50  = 3. UART for Firmware Upgrade =
51 51  
52 52  == 3.1 General Instruction for UART update firmware ==
... ... @@ -54,24 +54,24 @@
54 54  
55 55  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
56 56  
57 - (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
50 + **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially.
58 58  
59 - (% style="color:blue" %)**Step2**(%%): Press (% style="color:blue" %)**Reset**(%%) button, the module will then boot into program mode.
52 + **Step2**: Press **Reset** button, the module will then boot into program mode.
60 60  
61 - (% style="color:blue" %)**Step3**(%%): Use (% style="color:blue" %)**TremoProgrammer**(%%) to update the firmware to LoRaST v4.
54 + **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4.
62 62  
63 - (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) position. Press Reset button again and module will run the new software.
56 + **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software.
64 64  
65 65  
66 -Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
59 +Below is the method for how to update via **TremoProgrammer:**
67 67  
68 68  1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
69 69  
70 -2.  Run** (% style="color:blue" %)TremoProgrammer.(%%)**
63 +2.  Run** TremoProgrammer.**
71 71  
72 -3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**
65 +3.  Choose software and set the address to **0x0800D000**
73 73  
74 -4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
67 +4. Rember to set BOOT Switch to FLASH after update
75 75  
76 76  [[image:image-20221224174341-4.png||height="471" width="374"]]
77 77  
... ... @@ -82,6 +82,3 @@
82 82  Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
83 83  
84 84  [[image:image-20221224174605-6.png||height="569" width="880"]]
85 -
86 -
87 -
image-20230329162900-1.png