From version < 15.3 >
edited by Xiaoling
on 2022/12/28 11:04
To version < 20.1 >
edited by Bei Jinggeng
on 2023/03/29 16:29
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -19,17 +19,29 @@
19 19  **PS-LB **
20 20  )))|(% style="width:120px" %)SIB|(% style="width:199px" %)Instruction|(% style="width:221px" %)Instruction
21 21  
22 -
23 -
24 24  = 2. UART for AT Commands =
25 25  
26 26  == 2.1 Generate software set up for AT Commands via UART ==
27 27  
28 28  
27 +(% start="1" style="list-style-type:decimal" %)
29 29  1. Use a general serial tool.
30 30  1. Connect PC to device's UART interface
31 31  1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
31 +1. (((
32 +The password is the last six characters of APPSKEY or PIN of box
32 32  
34 +Example:
35 +
36 +APPSKEY= 41 85 71 A7 5D 7E 54 52 25 58 74 85 96 14 74 85
37 +
38 +The password:147485
39 +
40 +[[image:image-20230329162900-1.png||height="302" width="648"]]
41 +
42 +
43 +)))
44 +
33 33  [[image:image-20221224170218-1.png||height="497" width="640"]]
34 34  
35 35  
... ... @@ -39,7 +39,6 @@
39 39  [[image:image-20221224171304-3.png||height="545" width="863"]]
40 40  
41 41  
42 -
43 43  = 3. UART for Firmware Upgrade =
44 44  
45 45  == 3.1 General Instruction for UART update firmware ==
... ... @@ -47,24 +47,24 @@
47 47  
48 48  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
49 49  
50 - **Step1**: Set BOOT Switch to **PROG** mode. PROG mode is for update firmware specially.
61 + (% style="color:blue" %)**Step1**(%%): Set BOOT Switch to (% style="color:blue" %)**PROG**(%%) mode. PROG mode is for update firmware specially.
51 51  
52 - **Step2**: Press **Reset** button, the module will then boot into program mode.
63 + (% style="color:blue" %)**Step2**(%%): Press (% style="color:blue" %)**Reset**(%%) button, the module will then boot into program mode.
53 53  
54 - **Step3**: Use **TremoProgrammer** to update the firmware to LoRaST v4.
65 + (% style="color:blue" %)**Step3**(%%): Use (% style="color:blue" %)**TremoProgrammer**(%%) to update the firmware to LoRaST v4.
55 55  
56 - **Step4**: Set BOOT Switch to **FLASH** position. Press Reset button again and module will run the new software.
67 + (% style="color:blue" %)**Step4**(%%): Set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) position. Press Reset button again and module will run the new software.
57 57  
58 58  
59 -Below is the method for how to update via **TremoProgrammer:**
70 +Below is the method for how to update via (% style="color:blue" %)**TremoProgrammer:**
60 60  
61 61  1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
62 62  
63 -2.  Run** TremoProgrammer.**
74 +2.  Run** (% style="color:blue" %)TremoProgrammer.(%%)**
64 64  
65 -3.  Choose software and set the address to **0x0800D000**
76 +3.  Choose software and set the address to (% style="color:blue" %)**0x0800D000**
66 66  
67 -4. Rember to set BOOT Switch to FLASH after update
78 +4. Rember to set BOOT Switch to (% style="color:blue" %)**FLASH**(%%) after update
68 68  
69 69  [[image:image-20221224174341-4.png||height="471" width="374"]]
70 70  
... ... @@ -75,3 +75,6 @@
75 75  Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
76 76  
77 77  [[image:image-20221224174605-6.png||height="569" width="880"]]
89 +
90 +
91 +
image-20230329162900-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +217.0 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved