From version < 15.1 >
edited by Edwin Chen
on 2022/12/24 17:48
To version < 13.1 >
edited by Edwin Chen
on 2022/12/24 17:47
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,13 +1,5 @@
1 -**Table of Contents:**
1 += LoRaST v4 base Hardware =
2 2  
3 -{{toc/}}
4 -
5 -
6 -
7 -
8 -
9 -= 1. LoRaST v4 base Hardware =
10 -
11 11  Below hardware use LoRaST v4 module. They module support UART Access for AT Command and Firmware Upgrade.
12 12  
13 13  (% border="1" cellspacing="10" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#f7faff; width:770px" %)
... ... @@ -16,12 +16,10 @@
16 16  **PS-LB **
17 17  )))|(% style="width:135px" %)SIB|(% style="width:199px" %)Instruction|(% style="width:230px" %)Instruction
18 18  
11 += UART for AT Commands =
19 19  
13 +== Generate software set up for AT Commands via UART ==
20 20  
21 -= 2. UART for AT Commands =
22 -
23 -== 2.1 Generate software set up for AT Commands via UART ==
24 -
25 25  1. Use a general serial tool.
26 26  1. Connect PC to device's UART interface
27 27  1. Set up serial tool with : BaudRate: 9600, databit:8, No parity, No flow control.
... ... @@ -29,15 +29,15 @@
29 29  [[image:image-20221224170218-1.png||height="497" width="640"]]
30 30  
31 31  
32 -== 2.2 UART Connection for SIB mother board ==
22 +== UART Connection for SIB mother board ==
33 33  
34 34  [[image:image-20221224171304-3.png||height="545" width="863"]]
35 35  
36 36  
37 37  
38 -= 3. UART for Firmware Upgrade =
28 += UART for Firmware Upgrade =
39 39  
40 -== 3.1 General Instruction for UART update firmware ==
30 +== General Instruction for UART update firmware ==
41 41  
42 42  LoRaSTv4 Base hardware support UART update firmware. the UART connection is the same as AT Command connection, with the need for two extra action. See below for the steps:
43 43  
... ... @@ -54,7 +54,7 @@
54 54  
55 55  1.  Software download link:  [[https:~~/~~/www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0>>url:https://www.dropbox.com/sh/j0qyc7a9ejit7jk/AACtx2tK4gEv6YFXMIVUM4dLa?dl=0]]
56 56  
57 -2.  Run** TremoProgrammer.**
47 +2.  Run** TremoProgrammer.**
58 58  
59 59  3.  Choose software and set the address to **0x0800D000**
60 60  
... ... @@ -63,7 +63,7 @@
63 63  [[image:image-20221224174341-4.png||height="471" width="374"]]
64 64  
65 65  
66 -== 3.2 UART Connection for SIB mother board for Program. ==
56 +== UART Connection for SIB mother board for Program. ==
67 67  
68 68  Below shows the SIB board UART connection, reset button and BOOT Switch (Program Jumper) position. They can be used for firmware upgrade reference.
69 69  