<
From version < 80.1 >
edited by Kilight Cao
on 2023/11/21 10:45
To version < 81.1 >
edited by Kilight Cao
on 2023/11/21 10:49
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -160,14 +160,20 @@
160 160  [[image:image-20231101163743-4.png||height="528" width="1024"]]
161 161  
162 162  
163 +== 3.3 Step 3: Configure frequency ==
163 163  
164 -== 3.3  Step 3: Access the gateway GUI ==
165 165  
166 +(% style="color:red" %)**Note:** **The Dragino gateway supports only one Channel plan**
166 166  
168 +[[image:image-20231121102920-1.png||height="531" width="1028"]]
169 +
170 +== 3.4  Step 4: Access the gateway GUI ==
171 +
172 +
167 167  User need to upload the TLS certificate and configure the LNS URI
168 168  
169 169  
170 -== 3.4  Step 4: Configure Station ==
176 +== 3.5  Step 5: Configure Station ==
171 171  
172 172  
173 173  User need to input Server URI, Server CUPS Key and LNS Key, as well as install CUPS certificate.
... ... @@ -174,19 +174,25 @@
174 174  
175 175  (% style="color:blue" %)**just to clarify:**
176 176  
177 - Server URI  ~-~->  Server Address, Example: wss:~/~/ap2.loriot.io:717
178 - TLS CA Certificate         ~-~-> 
179 - TLS Key  ~-~-> 
180 - TLS Certificate  ~-~->   
183 +(% class="box" %)
184 +(((
185 + Server URI  ~-~->  Server Address, Example: **wss:~/~/ap2.loriot.io:717**
186 + TLS CA Certificate         ~-~->  (% style="color:red" %)**DigiCert_Global_Root_G2.crt **(%%)
187 + TLS Key  ~-~->  (% style="color:red" %)**"Gateway EUI".gws.loriot.io.key**(%%)
188 + TLS Certificate  ~-~->    (% style="color:red" %)**"Gateway EUI".gws.loriot.io.crt**
189 +)))
181 181  
191 +(% class="wikigeneratedid" %)
192 +[[image:image-20231121104529-3.png||height="525" width="1032"]]
182 182  
183 -== 3.5  Start Station ==
184 184  
195 +== 3.6  Start Station ==
185 185  
197 +
186 186  When the user has finished the configuration, Please click "Save&Apply" to start station to connect LORIOT.
187 187  
188 188  
189 -== 3.6  Check Connection ==
201 +== 3.7  Check Connection ==
190 190  
191 191  
192 192  If user completes the above steps,which will see Log in the LORIOT.
... ... @@ -194,7 +194,7 @@
194 194  [[image:image-20231101165306-5.png||height="542" width="1050"]]
195 195  
196 196  
197 -== 3.7  Trouble Shooting ==
209 +== 3.8  Trouble Shooting ==
198 198  
199 199  
200 200  User can check the station log in the** LogRead ~-~-> System Log **page.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0