<
From version < 62.1 >
edited by Xiaoye
on 2022/11/12 16:32
To version < 61.1 >
edited by Xiaoye
on 2022/11/12 16:26
>
Change comment: Uploaded new attachment "image-20221112162644-4.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -72,6 +72,7 @@
72 72  
73 73  * Reboot device.
74 74  
75 +
75 75  == **1.3  Monitor Public IP** ==
76 76  
77 77  
... ... @@ -88,7 +88,7 @@
88 88  
89 89  = **2.  Remote Access** =
90 90  
91 -= **2.1  Remote Access via Remote.it.** =
92 +== **2.1  Remote Access via Remote.it.** ==
92 92  
93 93  
94 94  Remote.it for remote access is available in the latest Dragino firmware for gateway. For security concern, the remote.it only available base on end user demand.
... ... @@ -136,39 +136,9 @@
136 136  
137 137  
138 138  
139 -== **How to save the registered remote after the gateway's firmware update.** ==
140 +=== **2.1.1  How to register hp0d with Remote.it** ===
140 140  
141 -Before version [[lgw~-~-build-v5.4.1668240318-20221112-1606>>http://repo.dragino.com/release/miscellaneous/remoteit/dragino-lgw--v5.4.1668240318-squashfs-sysupgrade.bin]], once the gateway firmware is upgraded the remote configuration is gone.
142 142  
143 -This issue is now corrected:
144 -
145 -
146 -=== The gateway version is lower than **lgw~-~-build-v5.4.1668240318-20221112-1606:** ===
147 -
148 -~1. upload the [[backup file>>http://repo.dragino.com/release/miscellaneous/remoteit/backup.tar.gz]] to update the configuration.
149 -
150 -
151 -[[image:image-20221112162644-4.png]]
152 -
153 -2. Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware.
154 -
155 -
156 -[[image:image-20221112162543-2.png]]
157 -
158 -
159 -=== The gateway version is greater or equal to  **lgw~-~-build-v5.4.1668240318-20221112-1606:** ===
160 -
161 -
162 -~1. Only to do: Check the 'Preserver Settings' check box when you upgrade the gateway with the firmware.
163 -
164 -
165 -[[image:image-20221112162547-3.png]]
166 -
167 -
168 -
169 -== **2.1.1  How to register hp0d with Remote.it** ==
170 -
171 -
172 172  **Prerequisites:**
173 173  
174 174  Users must have an account and APP for remote.it
... ... @@ -176,7 +176,7 @@
176 176  [[https:~~/~~/app.remote.it>>https://app.remote.it]]
177 177  
178 178  
179 -=== (% style="color:blue" %)**1.  Click "+" in the APP to add a device**(%%) ===
150 +(% style="color:blue" %)**1.  Click "+" in the APP to add a device**
180 180  
181 181  Then click Add "Linux & Raspberry Pi" and the APP will generate a command to register the device.
182 182  
... ... @@ -185,7 +185,7 @@
185 185  
186 186  
187 187  
188 -=== (% style="color:blue" %)**2.  Copy the register device command**(%%) ===
159 +(% style="color:blue" %)**2.  Copy the register device command**
189 189  
190 190  
191 191  [[image:image-20220815173944-2.jpeg||height="556" width="923"]]
... ... @@ -192,7 +192,7 @@
192 192  
193 193  
194 194  
195 -=== (% style="color:blue" %)**3.  Enter the command copied from the previous step on the HP0D Linux command line**(%%) ===
166 +(% style="color:blue" %)**3.  Enter the command copied from the previous step on the HP0D Linux command line**
196 196  
197 197  
198 198  [[image:image-20220815173951-3.jpeg||height="424" width="1147"]]
... ... @@ -199,7 +199,7 @@
199 199  
200 200  
201 201  
202 -=== (% style="color:blue" %)**4.  Check whether the device is successfully registered on the Remote.it APP**(%%) ===
173 +(% style="color:blue" %)**4.  Check whether the device is successfully registered on the Remote.it APP**
203 203  
204 204  
205 205  [[image:image-20220815173958-4.jpeg||height="580" width="964"]]
... ... @@ -206,10 +206,10 @@
206 206  
207 207  
208 208  
209 -== **2.1.2  Trouble Shooting** ==
180 +=== **2.1.2  Trouble Shooting** ===
210 210  
211 211  
212 -=== **1. What should users do when gateway Remote.it installation fails** ===
183 +==== **What should users do when gateway Remote.it installation fails** ====
213 213  
214 214  
215 215  [[image:image-20220907162028-4.png||height="564" width="1148"]]
... ... @@ -229,10 +229,9 @@
229 229  (% style="color:blue" %)**Step 3:**(%%) Follow the [[Remoteit user instruction for Dragino Gateway>>https://www.remote.it/getting-started/dragino]] steps to reconfigure
230 230  
231 231  
203 +== **2.2  RSSH Introduction** ==
232 232  
233 -= **2.2  RSSH Introduction** =
234 234  
235 -
236 236  Reverse SSH for remote access is available in the latest Dragino firmware for gateway. For security concern, the RSSH only available base on end user demand.
237 237  
238 238  (% style="color:red" %)**Important Notice:**
... ... @@ -255,6 +255,8 @@
255 255  * MS14 series if installed with the same firmware.
256 256  
257 257  
228 +
229 +
258 258  === **2.2.1  End User Guide to use SSH access** ===
259 259  
260 260  
... ... @@ -485,3 +485,4 @@
485 485  
486 486  [[image:image-20220531153219-17.png]]
487 487  
460 +
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0