Changes for page End Device AT Commands and Downlink Command
Last modified by Mengting Qiu on 2024/06/05 10:57
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -714,14 +714,17 @@ 714 714 715 715 Feature: Get or Set the delay between the end of the Tx and the Rx Window 2 in ms 716 716 717 -AT Command:AT+RX2DL 717 +{{info}} 718 +**AT Command:AT+RX2DL** 719 +{{/info}} 718 718 719 -|=(% colspan="3" %)AT+RX2DL 720 -|**Command Example**|**Function**|**Response** 721 -|AT+RX2DL=?|Get the delay.|2000((( 721 +(% style="background-color:#ffffcc; color:green; width:481.222px" %) 722 +|=(% colspan="3" style="width: 478px;" %)AT+RX2DL 723 +|(% style="width:175px" %)**Command Example**|(% style="width:152px" %)**Function**|(% style="width:150px" %)**Response** 724 +|(% style="width:175px" %)AT+RX2DL=?|(% style="width:152px" %)Get the delay.|(% style="width:150px" %)2000((( 722 722 OK 723 723 ))) 724 -|AT+RX2DL=2500|Set the delay.|OK((( 727 +|(% style="width:175px" %)AT+RX2DL=2500|(% style="width:152px" %)Set the delay.|(% style="width:150px" %)OK((( 725 725 726 726 ))) 727 727 ... ... @@ -729,14 +729,17 @@ 729 729 730 730 Feature: Get or Set the Rx2 window data rate (0-7 corresponding to DR_X) 731 731 732 -AT Command:AT+RX2DR 735 +{{info}} 736 +**AT Command:AT+RX2DR** 737 +{{/info}} 733 733 734 -|=(% colspan="3" %)AT+RX2DR 735 -|**Command Example**|**Function**|**Response** 736 -|AT+RX2DR=?|Get the Rx2 window data rate.|2((( 739 +(% style="background-color:#ffffcc; color:green; width:525.222px" %) 740 +|=(% colspan="3" style="width: 522px;" %)AT+RX2DR 741 +|(% style="width:160px" %)**Command Example**|(% style="width:232px" %)**Function**|(% style="width:130px" %)**Response** 742 +|(% style="width:160px" %)AT+RX2DR=?|(% style="width:232px" %)Get the Rx2 window data rate.|(% style="width:130px" %)2((( 737 737 OK 738 738 ))) 739 -|AT+RX2DR=6|Set the Rx2 window data rate.|OK((( 745 +|(% style="width:160px" %)AT+RX2DR=6|(% style="width:232px" %)Set the Rx2 window data rate.|(% style="width:130px" %)OK((( 740 740 741 741 ))) 742 742 ... ... @@ -744,14 +744,17 @@ 744 744 745 745 Feature: Get or Set the Rx2 window frequency 746 746 747 -AT Command:AT+RX2FQ 753 +{{info}} 754 +**AT Command:AT+RX2FQ** 755 +{{/info}} 748 748 749 -|=(% colspan="3" %)AT+RX2FQ 750 -|**Command Example**|**Function**|**Response** 751 -|AT+RX2FQ=?|Get the Rx2 window frequency.|434665000((( 757 +(% style="background-color:#ffffcc; color:green; width:587.222px" %) 758 +|=(% colspan="3" style="width: 584px;" %)AT+RX2FQ 759 +|(% style="width:183px" %)**Command Example**|(% style="width:240px" %)**Function**|(% style="width:160px" %)**Response** 760 +|(% style="width:183px" %)AT+RX2FQ=?|(% style="width:240px" %)Get the Rx2 window frequency.|(% style="width:160px" %)434665000((( 752 752 OK 753 753 ))) 754 -|AT+RX2FQ=434665000|Set the Rx2 window frequency.|OK((( 763 +|(% style="width:183px" %)AT+RX2FQ=434665000|(% style="width:240px" %)Set the Rx2 window frequency.|(% style="width:160px" %)OK((( 755 755 756 756 ))) 757 757 ... ... @@ -759,14 +759,17 @@ 759 759 760 760 Feature: Get or Set the Transmit Power(0-5, MAX:0, MIN:5, according to LoRaWAN Spec, or 40=10dB, 41 = 11dB, …, 50 = 20dB which is out of LoRaWAN spec. ) 761 761 762 -AT Command:AT+TXP 771 +{{info}} 772 +**AT Command:AT+TXP** 773 +{{/info}} 763 763 764 -|=(% colspan="3" %)AT+TXP 765 -|**Command Example**|**Function**|**Response** 766 -|AT+TXP=?|Get the Transmit Power.|0((( 775 +(% style="background-color:#ffffcc; color:green; width:465.222px" %) 776 +|=(% colspan="3" style="width: 462px;" %)AT+TXP 777 +|(% style="width:161px" %)**Command Example**|(% style="width:189px" %)**Function**|(% style="width:112px" %)**Response** 778 +|(% style="width:161px" %)AT+TXP=?|(% style="width:189px" %)Get the Transmit Power.|(% style="width:112px" %)0((( 767 767 OK 768 768 ))) 769 -|AT+TXP=1|Set the Transmit Power.|OK((( 781 +|(% style="width:161px" %)AT+TXP=1|(% style="width:189px" %)Set the Transmit Power.|(% style="width:112px" %)OK((( 770 770 771 771 ))) 772 772 ... ... @@ -774,18 +774,21 @@ 774 774 775 775 If the downlink payload=22000100, it means setting the TXP to 0. 776 776 777 -* Example 1: Downlink Payload: 22000102 ~/~/ Set AT+TXP=2. 778 -* Example 2: Downlink Payload: 220000FF ~/~/ Set AT+TXP=0. 789 +* **Example 1**: Downlink Payload: **22000102** ~/~/ Set AT+TXP=2. 790 +* **Example 2**: Downlink Payload: **220000FF** ~/~/ Set AT+TXP=0. 779 779 780 780 == 7.15 RSSI of the Last Received Packet == 781 781 782 782 Feature: Get or Set the Rx2 window frequency 783 783 784 -AT Command:AT+RSSI 796 +{{info}} 797 +**AT Command:AT+RSSI** 798 +{{/info}} 785 785 786 -|=(% colspan="3" %)AT+RSSI 787 -|**Command Example**|**Function**|**Response** 788 -|AT+RSSI=?|Get the RSSI of the last received packet.|0((( 800 +(% style="background-color:#ffffcc; color:green; width:557.222px" %) 801 +|=(% colspan="3" style="width: 554px;" %)AT+RSSI 802 +|(% style="width:164px" %)**Command Example**|(% style="width:289px" %)**Function**|(% style="width:100px" %)**Response** 803 +|(% style="width:164px" %)AT+RSSI=?|(% style="width:289px" %)Get the RSSI of the last received packet.|(% style="width:100px" %)0((( 789 789 OK 790 790 ))) 791 791 ... ... @@ -793,11 +793,14 @@ 793 793 794 794 Feature: Get the SNR of the last received packet 795 795 796 -AT Command:AT+SNR 811 +{{info}} 812 +**AT Command:AT+SNR** 813 +{{/info}} 797 797 798 -|=(% colspan="3" %)AT+SNR 799 -|**Command Example**|**Function**|**Response** 800 -|AT+SNR=?|Get the RSSI of the last received packet.|0((( 815 +(% style="background-color:#ffffcc; color:green; width:571.222px" %) 816 +|=(% colspan="3" style="width: 568px;" %)AT+SNR 817 +|(% style="width:164px" %)**Command Example**|(% style="width:290px" %)**Function**|(% style="width:113px" %)**Response** 818 +|(% style="width:164px" %)AT+SNR=?|(% style="width:290px" %)Get the RSSI of the last received packet.|(% style="width:113px" %)0((( 801 801 OK 802 802 ))) 803 803 ... ... @@ -805,73 +805,89 @@ 805 805 806 806 Feature: Get or set the application port. 807 807 808 -AT Command: AT+PORT 826 +{{info}} 827 +**AT Command: AT+PORT** 828 +{{/info}} 809 809 810 -|=(% colspan="3" %)AT+PORT 811 -|**Command Example**|**Function**|**Response** 812 -|AT+PORT=?|Get the application port|21((( 830 +(% style="background-color:#ffffcc; color:green; width:500.222px" %) 831 +|=(% colspan="3" style="width: 497px;" %)AT+PORT 832 +|(% style="width:157px" %)**Command Example**|(% style="width:204px" %)**Function**|(% style="width:135px" %)**Response** 833 +|(% style="width:157px" %)AT+PORT=?|(% style="width:204px" %)Get the application port|(% style="width:135px" %)21((( 813 813 OK 814 814 ))) 815 -|AT+PORT=21|Set the application port|OK 836 +|(% style="width:157px" %)AT+PORT=21|(% style="width:204px" %)Set the application port|(% style="width:135px" %)OK 816 816 817 -Downlink Command: 0x23 838 +{{info}} 839 +**Downlink Command: 0x23** 840 +{{/info}} 818 818 819 819 Format: Command Code (0x23) followed by 1 bytes port value. 820 820 821 821 If the downlink payload=2301, it means set the application port to 1, while type code is 23. 822 822 823 -* Example 1: Downlink Payload: 2301 ~/~/ set the application port to 1 824 -* Example 2: Downlink Payload: 2305 ~/~/ set the application port to 5 846 +* **Example 1**: Downlink Payload: **2301** ~/~/ set the application port to 1 847 +* **Example 2**: Downlink Payload:** 2305** ~/~/ set the application port to 5 825 825 826 826 == 7.18 Single Channel Mode == 827 827 828 828 Feature:Get or Set Frequency (Unit: Hz) for Single Channel Mode. 829 829 830 -AT Command: AT+CHS 853 +{{info}} 854 +**AT Command: AT+CHS** 855 +{{/info}} 831 831 832 -|=(% colspan="3" %)AT+CHS 833 -|**Command Example**|**Function**|**Response** 834 -|AT+CHS=?|Get Frequency for Single Channel Mode|0((( 857 +(% style="background-color:#ffffcc; color:green; width:603.222px" %) 858 +|=(% colspan="3" style="width: 600px;" %)AT+CHS 859 +|(% style="width:182px" %)**Command Example**|(% style="width:295px" %)**Function**|(% style="width:122px" %)**Response** 860 +|(% style="width:182px" %)AT+CHS=?|(% style="width:295px" %)Get Frequency for Single Channel Mode|(% style="width:122px" %)0((( 835 835 OK 836 836 ))) 837 -|AT+CHS=868100000|Set Frequency for Single Channel Mode|OK 863 +|(% style="width:182px" %)AT+CHS=868100000|(% style="width:295px" %)Set Frequency for Single Channel Mode|(% style="width:122px" %)OK 838 838 839 839 == 7.19 Eight Channel Mode == 840 840 841 841 Feature: Get or Set eight channels mode,Only for US915,AU915,CN470. 842 842 843 -AT Command: AT+CHE 869 +{{info}} 870 +**AT Command: AT+CHE** 871 +{{/info}} 844 844 845 -|=(% colspan="3" %)AT+CHE 846 -|**Command Example**|**Function**|**Response** 847 -|AT+CHE=?|Get eight channels mode|1((( 873 +(% style="background-color:#ffffcc; color:green; width:710.222px" %) 874 +|=(% colspan="3" style="width: 707px;" %)AT+CHE 875 +|(% style="width:160px" %)**Command Example**|(% style="width:198px" %)**Function**|(% style="width:349px" %)**Response** 876 +|(% style="width:160px" %)AT+CHE=?|(% style="width:198px" %)Get eight channels mode|(% style="width:349px" %)1((( 848 848 902.3 902.5 902.7 902.9 903.1 903.3 903.5 903.7 849 849 850 850 OK 851 851 ))) 852 -|AT+CHE=1|Set eight channels mode|OK 881 +|(% style="width:160px" %)AT+CHE=1|(% style="width:198px" %)Set eight channels mode|(% style="width:349px" %)OK 853 853 854 -Downlink Command: 0x24 883 +{{info}} 884 +**Downlink Command: 0x24** 885 +{{/info}} 855 855 856 856 Format: Command Code (0x24) followed by 1 bytes channel value. 857 857 858 858 If the downlink payload=2401, it means set channel mode to 1, while type code is 24. 859 859 860 -* Example 1: Downlink Payload: 2401 ~/~/ set channel mode to 1 861 -* Example 2: Downlink Payload: 2405 ~/~/ set channel mode to 5 891 +* **Example 1**: Downlink Payload: 2401 ~/~/ set channel mode to 1 892 +* **Example 2**: Downlink Payload: 2405 ~/~/ set channel mode to 5 862 862 863 863 == 7.20 Get or Set RXwindows1 timeout == 864 864 865 865 Feature:Get or Set the number of symbols to detect and timeout from RXwindow1(0 to 255). 866 866 867 -AT Command: AT+RX1WTO 898 +{{info}} 899 +**AT Command: AT+RX1WTO** 900 +{{/info}} 868 868 869 -|=(% colspan="3" %)AT+ RX1WTO 870 -|**Command Example**|**Function**|**Response** 871 -|AT+RX1WTO=?|Get RXwindows1 timeout|14((( 902 +(% style="background-color:#ffffcc; color:green; width:460.222px" %) 903 +|=(% colspan="3" style="width: 457px;" %)AT+ RX1WTO 904 +|(% style="width:163px" %)**Command Example**|(% style="width:201px" %)**Function**|(% style="width:93px" %)**Response** 905 +|(% style="width:163px" %)AT+RX1WTO=?|(% style="width:201px" %)Get RXwindows1 timeout|(% style="width:93px" %)14((( 872 872 OK 873 873 ))) 874 -|AT+RX1WTO=60|Set RXwindows1 timeout|OK 908 +|(% style="width:163px" %)AT+RX1WTO=60|(% style="width:201px" %)Set RXwindows1 timeout|(% style="width:93px" %)OK 875 875 876 876 AT+RX1TWO is theRxSingle timeout value of receive window 1. If it is not set, then the queriedvalue is the default value. If it is set, then the queried value is the setvalue. AT+RX2TWO is thesame as above. The definitionof RxSingle timeout is as described in the following paragraph. 877 877