Table of Contents:
There are some new models of Dragino sensors support OTA update via Private LoRa Protocol, (Even the sensor runs LoRaWAN protocol by default).
User can use the OTA update to update the configure file or firmware to the sensors.
Here list the models that support OTA Update.
Models | Firmware Version | Comments |
---|---|---|
RS485-LB/LS | All firmware version | |
SN50v3-LB | All firmware version | |
PS-LB-NA | All firmware version | |
TS01-LB/LS | All firmware version | |
CS01-LB | All firmware version | |
AIS01-LB | All firmware version | |
TC01-LB/ TC11-LB | All Firmware Version | |
LHT65N | All Firmware Version | |
LHT65N-PIR,LHT65N-E31F | All Firmware Version | |
D20-LB/D20S-LB/D22-LB/D23-LB | All Firmware Version | |
S31/S31B-LB/LS | All Firmware Version | |
AQS01-L | All Firmware Version | |
UV254-LB | All Firmware Version | |
SDI-12-LB/LS | All Firmware Version | |
SE01-LB/LS | All Firmware Version | |
PS-LB | All Firmware Version | |
SE02-LB | All Firmware Version | |
SPH01-LB/LS | All Firmware Version | |
LMS01-LB/LS | All Firmware Version | |
WL03A-LB/LS | All Firmware Version | |
DS03A-LB/LS | All Firmware Version | |
CPL03-LB/LS | All Firmware Version | |
SW3L-LB/LS | All Firmware Version | |
LCC01-LB | All Firmware Version | |
PS-LB/LS | All Firmware Version | |
LDS12-LB/LS | All Firmware Version | |
LDS40-LB/LS | All Firmware Version | |
DDS75-LB/LS | All Firmware Version | |
DDS45-LB/LS | All Firmware Version | |
DDS20-LB/LS | All Firmware Version | |
DDS04-LB/LS | All Firmware Version | |
MDS120-LB/LS | All Firmware Version | |
MDS200-LB/LS | All Firmware Version | |
DS20L | All Firmware Version |
Video Instruction: -- OTA Upgrade Firmware (via LoRa) of LoRaWAN Sensors: https://youtu.be/SSvOqvBrwGg
After press reset button, LA66 USB will restart and broadcast update process with the Dev EUI and Password.
In every reboot/ reactivate, the end node will check if there is update request. If end node gets the update request from LA66. End node will check if the Dev EUI and Password match. If match, End node will establish connection with LA66 USB for OTA update.
Below shows the update successul result.
Video Instruction: -- OTA Upgrade Configure (via LoRa) of LoRaWAN Sensors: https://youtu.be/5XedoNVkbQQ
OTA Update Configure is good for batch update configure in same type of sensors.
If user doesn't have LA66 USB Adapter, they can still use other Dragino Device to connect to PC for OTA update.
Steps:
Each device has a shipped label with OTA Password which is 16 chars. like below. If user don't find this, please send us a photo for the device with Dev EUI to support@dragino.com . and we will search the password for you.
OTA update is done via Bootloader and only change the firmware partition. So update a crash firmware via OTA update won't destroy bootloader and user can use OTA method to update again.
Here are notice:
1. OTA update frequency depend on the firmware frequency. If there is no frequency in the firmware. Bootloader will use EU868 as default frequency.
2. OTA update require a reset or reactivate action. If the crash firmware doesn't have them work, user need to manuall push the physic reset button on the PCB or power off/on device.
1. If user click "Start" but there is issue during update. User may need to close and open the tool again.